MTTM. UHI-Energy efficiency. MIC 2015 Guidelines.
4. Applications of films and screens
Solar shading plays a fundamental role in controlling heat and light gain through a building’s glazed surfaces.
The term ‘shading’ refers to any element, whether fixed or movable, capable of partially or completely limiting the entry of solar radiation into interior spaces [Grosso, Raimondo].
The effectiveness of such systems depends on the amount of radiation intercepted, the absorption and reflection properties of the materials, and correct design with regard to:
- the building’s orientation;
- the seasonal path of the sun;
- the site’s latitude;
- the position of the shading system relative to the window frame.
In historic buildings, it is necessary to carefully assess the aesthetic and functional compatibility of shading systems, as these systems can significantly alter the appearance of the façades and the thermo-hygrometric behaviour of the building envelope.
Shading systems can be:
- natural or artificial;
- integrated into the building or situated in the surrounding area;
- internal or external;
- fixed or movable.
The use of climbing vegetation directly on historic surfaces is generally not recommended due to the potential damage to masonry and plasterwork.
Insulation and airtightness
Reducing heat loss through windows and doors requires controlling air infiltration between the frame and the building structure and improving the performance of glazed surfaces.
These measures make it possible to:
- improve thermal comfort;
- reduce energy loss;
- minimise condensation and mould;
- maintain good indoor air quality.
The main strategies include:
- sealing the frames;
- applying low-emissivity films;
- using insulating screens.
Sunshades
Shading systems help to control solar gain and visual comfort, helping to reduce overheating in summer without compromising heat gains in winter.
Shading systems can be integrated directly into the glazing or installed on the inside or outside of the building. Some high-performance systems use angle-selective technologies or chromogenic devices integrated into the cavity of double or triple glazing.
Interventions
In.11. Frame insulation and airtightness
The work involves sealing the joints between the frame and the masonry and fitting gaskets between the moving parts of the window or door, thereby improving airtightness and reducing draughts.
This solution is particularly well-suited to conservation-oriented restoration, as it preserves the original appearance of the historic window. Where necessary, it can be combined with work on the glazing or the application of insulating films.
In.12. Application of insulating or absorbing film to glass
The measure involves applying transparent low-emissivity films to glazed surfaces to improve the thermal resistance of the glass and reduce energy loss.
The work is minimally invasive and suitable for listed historic buildings, particularly when combined with improvements to the airtightness of the window frames.
In.19. Application of solar control films to glass
The measure involves the installation of solar control films to reduce heat gain where it is not possible to replace high-quality glazing and/or frames, provided that the window or door is generally in good condition.
In.20. Installations of internal screens
Internal shading systems offer good aesthetic compatibility and effective control of natural light, although they are less effective at reducing summer heat than external systems.