Skip links
X_1_4_cordoli_in_acciaio

MTTM. Earthquake

1. Interventions to reduce connection gaps
1.4. Insertion of steel curbs

MTTM-HEA-1.4

Description

Steel tie beams provide a structural reinforcement solution designed to improve the connections between walls and the interaction between masonry and the roof, with a minimal increase in mass and a high degree of reversibility. Thanks to their light weight and speed of installation, they represent a viable alternative to traditional tie beams, particularly in historic buildings. They can be constructed using a lattice structure comprising angle sections and flat metal plates arranged at the top and connected by reinforced bolts, or by means of sections or plates fixed to the two masonry faces and connected with through-bolts. The connection to the masonry is generally secured by reinforced bolts, possibly preceded by local reinforcement where there is deterioration or poor cohesion. When correctly designed, the parapet improves structural continuity, facilitates the transfer of horizontal forces between the roof and the walls, and limits out-of-plane overturning mechanisms. Its compatibility with timber roof structures makes this solution particularly suitable for historic buildings, as it avoids the introduction of excessively rigid elements.

Advantages

The steel beam improves the connection between the walls and the roof structure, promoting the building’s box-like behaviour during seismic events. Thanks to its lower weight compared to reinforced concrete beams, it limits the increase in seismic masses and allows for interventions that are generally minimally invasive, easily inspectable and characterised by a high degree of reversibility. Its good compatibility with timber roof structures makes it well-suited for use in historic buildings, whilst also helping to contain the horizontal forces from the roof. This solution is also particularly effective in buildings characterised by slender walls or high out-of-plane deformability.

Disadvantages and limitations of applicability

The effectiveness of the steel kerbs depends on the quality of the masonry in the anchorage areas and on the correct design of the connections between the metal elements and the masonry structure. Particular attention must be paid to corrosion protection and the durability of the works, especially in environments characterised by high humidity or aggressive conditions. Furthermore, where some metal elements remain exposed, the works may have an architectural impact that must be carefully assessed in buildings of historical interest. Finally, the correct installation of the anchors and the continuity of the system are essential conditions for ensuring the structural effectiveness of the works.

Synergies, interactions and opportunities for complementary interventions

Where masonry is deteriorated or lacks cohesion, it is advisable to first stabilise the top course affected by the anchors using suitable methods, such as mortar grouting or other local stabilisation techniques. Where the roof loads are particularly high, the design may provide for the integration of the parapet with load-containment systems, such as metal chains, in order to reduce the stresses transmitted to the masonry. It is also essential to verify the continuity of the connections between the parapet, the roof and the wind bracing walls, so that the system can effectively perform its intended connecting function.

Assessment against the criteria

Applicability and impact

Efficacy
Applicability
Environmental sustainability
Reversibility
Impact
Durability

****
****
*****
***
*****
*****

Cost and construction logistics

Monetary cost
Construction complexity
Availability (time)
Execution time
Maintenance costs
Regionality
Integrative interventions
Use restriction

***
***
****
***
*****
****
****
***

Production process

Degree of innovation
Sustainability

***
****

Relationship with the indicators of the Risk Analysis Model

Structural vulnerability: Links between structural elements. Roofs.

References

Borri, A., & De Maria, A. (2018). Masonry strengthening with composite materials. In: Strengthening and Retrofitting of Existing Structures.
Cattari, S., Lagomarsino, S., Bosiljkov, V., D’Ayala, D., et al. (2015). The guidelines for the seismic performance assessment of cultural heritage masonry structures by CEN TC346. Bulletin of Earthquake Engineering, 13, 927–965.
Consiglio Superiore dei Lavori Pubblici (2019). Circolare 21 gennaio 2019, n. 7 C.S.LL.PP. – Istruzioni per l’applicazione dell’Aggiornamento delle “Norme Tecniche per le Costruzioni” D.M. 17 gennaio 2018.
Doglioni, F., Moretti, A., & Petrini, V. (1994). Le chiese e il terremoto. LINT, Trieste.
ICOMOS (2003). Principles for the Analysis, Conservation and Structural Restoration of Architectural Heritage.
Lagomarsino, S., & Cattari, S. (2015). PERPETUATE Guidelines for Seismic Performance-Based Assessment of Cultural Heritage Masonry Structures. Bulletin of Earthquake Engineering, 13, 13–47.
Ministero dei Beni e delle Attività Culturali e del Turismo (2011). Linee guida per la valutazione e riduzione del rischio sismico del patrimonio culturale con riferimento alle Norme Tecniche per le Costruzioni di cui al D.M. 14 gennaio 2008.
Ministero delle Infrastrutture e dei Trasporti (2018). Aggiornamento delle Norme Tecniche per le Costruzioni. D.M. 17 gennaio 2018.
Roca, P., Cervera, M., Gariup, G., & Pelà, L. (2010). Structural Analysis of Masonry Historical Constructions: Classical and Advanced Approaches. Archives of Computational Methods in Engineering, 17(3), 299–325.
Tomaževič, M. (1999). Earthquake-Resistant Design of Masonry Buildings. Imperial College Press.