MTTM. Earthquake
1. Interventions to reduce connection gaps
1.2 Inserting hoops
MTTM-HEA-1.2
Description
The installation of hoops is a localised intervention aimed at reducing deficiencies in the structural connections of masonry buildings and limiting the activation of local mechanisms during seismic events. The intervention generally involves the construction of confinement systems using metal frames or profiles suitably connected to the masonry, capable of redistributing stresses and improving the interaction between the various parts of the structure. Bracing is used to reinforce existing or newly created openings and to consolidate sections of masonry characterised by discontinuities or insufficient connections. It is classified as a repair or local intervention if it affects individual parts and/or elements of the structure and must not significantly alter its overall behaviour. In historic buildings, particular attention must be paid to the quality of the masonry, the design of the anchors and the minimisation of stress concentrations at the points of contact. The intervention must also ensure compatibility with the building’s construction characteristics, minimising the impact on the historic fabric and prioritising solutions that can be inspected and, where possible, reversed.
Advantages
The installation of tie-stays improves the local connections between structural elements and increases the load-bearing capacity of the affected sections of masonry, helping to reduce vulnerability in areas characterised by construction discontinuities. This measure is particularly effective for reinforcing existing or newly created openings and helps to limit the activation of local collapse mechanisms during seismic events. It is a well-established and extensively tested technique that can be effectively integrated with other seismic retrofitting measures as part of an overall strategy to reduce vulnerability.
Disadvantages and limitations of applicability
The effectiveness of the ring beams depends on the quality of the existing masonry and on the correct design of the connections between the reinforcement structure and the masonry. Where the masonry is severely degraded or poorly bonded, the intervention may prove less effective and require preliminary consolidation work. Furthermore, inadequate design can lead to localised stress concentrations in the anchorage areas, whilst the presence of metal elements may have an architectural impact that must be assessed with particular care in buildings of historical interest.
Synergies, interactions and opportunities for complementary interventions
The installation of tie-rods is frequently combined with other seismic retrofitting measures, such as the consolidation of masonry, the improvement of connections between walls and floor slabs, and the reinforcement of horizontal diaphragms, in order to enhance the building’s overall response to seismic forces. In cases where the masonry shows signs of deterioration or reduced load-bearing capacity, it may be necessary to first consolidate the areas affected by the anchors or to locally restore the continuity of the masonry to ensure the full effectiveness of the intervention.
Assessment against the criteria
Applicability and impact
Efficacy
Applicability
Environmental sustainability
Reversibility
Impact
Durability
****
***
*****
**
***
****
Cost and construction logistics
Monetary cost
Construction complexity
Availability (time)
Execution time
Maintenance costs
Regionality
Integrative interventions
Use restriction
****
***
****
***
*****
****
****
***
Production process
Degree of innovation
Sustainability
***
****
Relationship with the indicators of the Risk Analysis Model
Structural vulnerability: Links between structural elements.
Riferimenti
Borri, A., & De Maria, A. (2018). Masonry strengthening with composite materials. In: Strengthening and Retrofitting of Existing Structures.
Cattari, S., Lagomarsino, S., Bosiljkov, V., D’Ayala, D., et al. (2015). The guidelines for the seismic performance assessment of cultural heritage masonry structures by CEN TC346. Bulletin of Earthquake Engineering, 13, 927–965.
Consiglio Superiore dei Lavori Pubblici (2019). Circolare 21 gennaio 2019, n. 7 C.S.LL.PP. – Istruzioni per l’applicazione dell’Aggiornamento delle “Norme Tecniche per le Costruzioni” D.M. 17 gennaio 2018.
Doglioni, F., Moretti, A., & Petrini, V. (1994). Le chiese e il terremoto. LINT, Trieste.
ICOMOS (2003). Principles for the Analysis, Conservation and Structural Restoration of Architectural Heritage.
Lagomarsino, S., & Cattari, S. (2015). PERPETUATE Guidelines for Seismic Performance-Based Assessment of Cultural Heritage Masonry Structures. Bulletin of Earthquake Engineering, 13, 13–47.
Ministero dei Beni e delle Attività Culturali e del Turismo (2011). Linee guida per la valutazione e riduzione del rischio sismico del patrimonio culturale con riferimento alle Norme Tecniche per le Costruzioni di cui al D.M. 14 gennaio 2008.
Ministero delle Infrastrutture e dei Trasporti (2018). Aggiornamento delle Norme Tecniche per le Costruzioni. D.M. 17 gennaio 2018.
Roca, P., Cervera, M., Gariup, G., & Pelà, L. (2010). Structural Analysis of Masonry Historical Constructions: Classical and Advanced Approaches. Archives of Computational Methods in Engineering, 17(3), 299–325.
Tomaževič, M. (1999). Earthquake-Resistant Design of Masonry Buildings. Imperial College Press.