Urban Heat Islands and Energy Efficiency in Historic Buildings. MIC 2015 Guidelines

2. Replacement of windows and installation of glass
In.08. Replacement of glass with insulating or absorbing models on existing frames

MTTM-UHI_MIC-08

Description

Traditional glass does not have good thermal resistance properties. Replacing it with glazing that offers higher thermal resistance improves the energy performance of the building envelope by reducing heat loss through transmission. Fitting new glazing also reduces air infiltration between the glass and the frame. To optimise the work, it is advisable to seal the building envelope.
The measure involves replacing the existing glass with energy-efficient glazing, whilst retaining the original frame. The glass must balance the requirements for thermal insulation and solar control.

Advantages

Replacing a window results in:

  • a reduction in the thermal load associated with the windows of between 50 per cent and 1.85 per cent, depending on the type of glazing being replaced;
  • a reduction in solar heat gain through the windows of between 27 per cent and 145 per cent when using low-emissivity or selective glazing;

a reduction in air infiltration of up to 82 per cent with a high-seal window.

Disadvantages and limitations of applicability

Replacing the glazing with insulating or solar-collecting units helps to reduce heat loss from the building when technical constraints or aesthetic and historical considerations prevent the replacement of the entire window unit. In section 7, it is of fundamental importance to assess the mechanical strength, state of repair and thermal performance of the existing window frame.

Synergies, interactions and opportunities for complementary interventions

Glazing replacement involves the use of glazing types capable of balancing reduced heat loss with solar gain, based on an assessment of the energy requirements of the building or space. Taking into account the condition, material and dimensional characteristics, and the strength of the frame, one may opt for high-energy-performance glazing such as glass with selective coatings (M.S), insulating glass (M.6), energy-selective glass (M.7), chromogenic glass (M.9) and energy-efficient glass (M.8).
To optimise the renovation, it is advisable to seal any air leaks originating from the joints between the wall cavity and the frame (Fig. 11). Single glazing may be replaced with double glazing provided the frame is made of laminated solid timber, aluminium or thermally broken PVC, and is in a good state of repair with good air and water tightness

Assessment against the criteria

Applicability and impact

Efficacy
Applicability
Environmental sustainability
Reversibility
Impact
Quality of redevelopment
Durability

***
****
***
****
****
**
****

Cost and construction logistics

Monetary cost
Construction complexity
Availability (time)
Execution time
Maintenance costs
Regionality
Integrative interventions
Use restriction

****
****
***
****
***
***
***
****

Production process

Degree of innovation
Sustainability

****
****

Relationship with the indicators of the Risk Analysis Model

Formal vulnerability: Mitigations elements in the building – Roofs; Mitigations elements in the building – Facades.
Structural and building services vulnerabilities: Building envelope and its efficiency.

References

D.lgs 311.2006. Valori limite della trasmittanza termica “U” delle “chiusure trasparenti comprensive degli infissi” (i serramenti completi) e dei vetri.
UNI EN 14351-1; 2010. Finestre e porte – Norma di prodotto, caratteristiche prestazionali.
UNI EN ISO 10077. Prestazione termica di finestre, porte e chiusure oscuranti – Calcolo della trasmittanza termica.