Floors play a fundamental role in the seismic behaviour of masonry buildings, as they transfer horizontal forces to the walls running parallel to the direction of the earthquake and help to restrain the walls subjected to out-of-plane forces. To ensure this function, they must be effectively connected to the masonry, by means of suitable supports and, where necessary, devices that prevent the beams from slipping out of place.
Technical standards require the stiffness of floor slabs to be assessed in order to determine their effective capacity to function as diaphragms and promote the building’s box-like behaviour. However, it is not necessary in every case to aim for high in-plane stiffness: excessive stiffening can, in fact, alter the distribution of seismic forces, concentrating them on the stiffest elements or accentuating torsional effects. Limited and carefully calibrated stiffening is generally preferable, particularly in highly deformable floor slabs.
The problem particularly affects timber floors and pre-modern floors constructed from steel beams and vaulted arches, whilst modern concrete-and-brick floors often already possess sufficient rigidity. In timber floors, it is advisable to retain the existing structure as far as possible, not least because of its low dead weight.
Before carrying out any stiffening work, it is necessary to check and improve the connections between beams and masonry, including through the use of metal fittings. Increased stiffness can be achieved by installing a second layer of cross-laid boarding or by using metal or composite strips. Any intervention must also take into account any increase in seismic masses and its effects on the overall dynamic behaviour of the structure.
Bracing using metal tie rods increases the stiffness and strength in the plane of existing floor slabs, improving the transfer of horizontal forces to the walls. It is particularly suitable for historic buildings with timber, steel or brick floor slabs, as it is minimally invasive, lightweight and reversible. The system uses plates, bars or diagonal tie rods, often arranged in a St Andrew’s cross pattern, connected to the perimeter elements. Its effectiveness depends on the continuity of the bracing and the quality of the connections to the masonry.
The addition of a second timber deck increases the stiffness and strength in the plane of timber floors, whilst resulting in a modest increase in mass compared with concrete slabs. Particularly suitable for historic buildings, it preserves the original timber framework using compatible timber elements. The new planking, laid at right angles or at an angle and mechanically connected to the existing planking, improves the diaphragm function. If necessary, the work can be supplemented to also increase flexural stiffness and vertical load-bearing capacity.
The composite concrete floor slab increases the load-bearing capacity, flexural stiffness and in-plane stiffness of timber floors. It is installed on the upper face and connected to the beams by means of connectors, thereby achieving a composite timber-concrete behaviour. This intervention also improves the structure’s diaphragm function, but in historic buildings it can significantly alter the distribution of seismic forces. The increase in mass and stiffness, the floor-to-wall connections and the characteristics of the masonry must therefore be carefully assessed.
A reinforced lightweight concrete screed primarily increases the in-plane stiffness and strength of timber floor slabs, improving their behaviour as a diaphragm. Constructed as a thin reinforced layer connected to the timber framework and masonry, it limits the increase in permanent loads compared with a traditional floor slab. Its effectiveness depends on the continuity of the screed and the quality of the connections. The design of the intervention must avoid excessive stiffening whilst assessing its effects on the distribution of seismic forces within the building.