Arched and vaulted structures are among the most characteristic features of historic masonry architecture. Their structural behaviour is based primarily on the transmission of compressive forces and on the correct balance of the horizontal forces exerted on the supporting masonry. Changes to the structural behaviour, material deterioration, ground subsidence, seismic events or inappropriate interventions can compromise this equilibrium, leading to cracking, deformation and, in the most serious cases, the onset of collapse mechanisms.
Consolidation works must therefore aim to restore or improve the structural equilibrium, limiting the forces transmitted to the supporting elements and, where necessary, increasing the overall load-bearing capacity of the structure. The most common solutions include the installation of chains, the construction of buttresses or wall thickening, the use of composite material cladding, and the construction of sub-arches or reinforced arches. Conversely, the construction of concrete counter-vaults, whether reinforced or not, should generally be avoided, as this increases seismic mass, alters the original static behaviour and may compromise the historical and heritage value of the structure.
Where structural instability is present, it is also necessary to carry out preliminary work on the damage using compatible repair techniques, such as mortar injections, the insertion of struts or limited wall shoring, before subsequently addressing the causes that led to the instability. All interventions must be designed in accordance with the principles of compatibility, minimal intervention, reversibility (where possible) and recognisability, giving priority to solutions capable of preserving the structural behaviour and authenticity of the historic property.
The installation of tie rods is one of the most effective traditional methods for counteracting the horizontal forces exerted by arches and vaults on the supporting masonry. Chains, generally positioned at the spandrels, limit the separation of the walls and help to restore the structure’s static equilibrium. The intervention requires careful design of the position and pre-stressing, avoiding excessive stress concentrations. In historic buildings, priority should be given to solutions that are compatible, inspectable and, where possible, reversible, thereby minimising the impact on the original fabric.
The construction of buttresses or wall reinforcements is a traditional method designed to counteract the horizontal forces generated by arches and vaults, thereby increasing the load-bearing capacity of the supporting masonry and improving the overall stability of the building. The effectiveness of this intervention depends on correct geometry, adequate bonding with the existing masonry and the presence of suitable foundations. In historic buildings, this solution should only be adopted when strictly necessary, carefully assessing its architectural impact and compatibility with the historic structure.
The application of composite materials and the installation of sub-arches are measures designed to increase the load-bearing capacity of arches and vaults and to counteract the forces acting upon them. Reinforcement systems, generally applied to the upper surface, improve structural behaviour with only a slight increase in weight, whilst sub-arches introduce an additional load-bearing element capable of helping to absorb stresses. The design must be supported by specific structural analyses and give priority to materials and solutions compatible with the construction and conservation characteristics of the historic building.
Learn more -> Plating with composite material bands and creation of an under-arch
Reinforced arch is a strengthening technique that increases the load-bearing capacity of masonry arches by inserting post-tensioned steel cables, which induce a favourable state of compression within the structure. This intervention helps to maintain the pressure distribution within the load-bearing thickness of the arch, reducing the risk of hinge formation and collapse mechanisms. The design requires specific structural analyses, with particular attention paid to the anchors, the support elements and the compatibility of the intervention with the overall behaviour of the historic building.