1. Internal and external insulation

Thermal insulation measures aim to reduce heat exchange between the building and the external environment, improving the energy performance of the building envelope and indoor comfort. In temperate climates, these measures must address both winter heating and summer cooling needs, facilitating the control of heat flows and the optimization of the building’s passive performance.
In historic buildings, traditional massive masonry walls—often characterized by great thickness and moderate thermal conductivity—generally provide good thermal inertia and acceptable levels of insulation. Interventions can therefore focus on improving glazing, reducing air infiltration, and, where necessary, integrating insulation layers compatible with the building’s thermo-hygrometric behavior.

However, the installation of new insulation layers is a delicate process, as it can alter the historical and architectural characteristics of the building envelope and disrupt the moisture balance of the masonry, potentially leading to interstitial condensation. For this reason, natural and breathable materials—such as plant fibers, wool, perlite, or vermiculite—are generally more suitable, as they can accommodate the permeability of traditional structures [Tubi et al., 2009; Cerroni, 2010].
It is also necessary to consider the presence of thermal bridges, i.e., discontinuities in the building envelope that facilitate heat transfer and the formation of condensation. Reducing them requires continuity in the insulation system and careful design of the construction joints.

Interventions for internal and external insulation ->

2. Replacement of windows and installation of glass

In the energy balance of historic buildings, windows and doors are particularly critical elements, both in terms of heat loss through glass and frames and in terms of controlling natural ventilation [Caterina, 1989; Di Battista, 1975].
Interventions on transparent components must therefore simultaneously address:

  • thermal insulation;
  • solar gain;
  • natural lighting;
  • ventilation;
  • acoustic comfort;
  • aesthetic and historical-architectural quality of the structure.

In historic buildings, which are often characterized by high thermal inertia, the replacement or modification of windows and doors can alter the original bioclimatic behavior of the building envelope; for this reason, it is necessary to carefully evaluate the relationship between replaced elements and preserved components.
Intervention strategies can be categorized according to different levels of invasiveness, reversibility, and compatibility:

  • complete replacement of the window or door;
  • replacement of the glass while retaining the frame;
  • installation of double glazing or secondary glazing;
  • improvement of airtightness;
  • application of special films;
  • integration of internal or external shading systems.

Interventions for replacement of windows and installation of glass ->

3. Interventions on the slab

The opaque lower closures of historic buildings regulate heat exchange with the ground, which is characterized by smaller temperature fluctuations than the external environment.
Interventions on these components can contribute both to improved winter heating—by limiting heat loss—and to summer cooling—by utilizing the ground as a natural heat sink.

In historic buildings, ground-level floors and traditional flooring often have different construction characteristics than those found in contemporary buildings, featuring porous materials, insufficient or absent crawl spaces, and limited natural ventilation systems. These conditions can significantly influence the building’s thermal and hygrometric behavior and the durability of the materials.
Improvement measures may include the installation of insulation layers, the creation or restoration of ventilated cavities, the improvement of crawl space ventilation, and the adoption of systems capable of limiting heat loss without compromising the breathability of historic structures.

Particular attention must be paid to issues of rising damp and condensation, which are very common in historic buildings. For this reason, it is generally advisable to incorporate waterproofing systems and, where compatible with the thermo-hygrometric behavior of the building envelope, vapor barriers and breathable materials.
It is also important to consider that overly waterproof or incompatible interventions can alter the hygrometric balance of the masonry, leading to moisture accumulation and surface or structural degradation. The design must therefore be based on a careful assessment of environmental conditions, the original construction characteristics, and the relationship between the building envelope and the ground.

Interventions on the slab ->

4. Film and Screen Installation – Insulation and Airtightness, Solar Shading

Solar shading plays a fundamental role in controlling heat and light gain through a building’s transparent surfaces.
The term “shading” refers to any element, whether fixed or movable, capable of partially or completely limiting the entry of solar radiation into interior spaces [Grosso, Raimondo].
The effectiveness of such systems depends on the amount of radiation intercepted, the absorption and reflection properties of the materials, and proper design with respect to:

  • the building’s orientation;
  • the seasonal path of the sun;
  • the site’s latitude;
  • the position of the shading system relative to the window.

In historic buildings, it is necessary to carefully evaluate the aesthetic and functional compatibility of shading systems, as these systems can significantly alter the appearance of facades and the thermo-hygrometric behavior of the building envelope.
Shading systems can be:

  • natural or artificial;
  • integrated into the building or placed in the surrounding area;
  • internal or external;
  • fixed or movable.

The use of climbing vegetation directly on historic surfaces is generally discouraged due to potential damage to masonry and plaster.

Applications of films and screens ->

5. Installation of lighting and ventilation systems

Solar radiation contributes to both the heat gain and natural lighting of buildings. Solar control strategies must therefore balance heating and cooling requirements with those related to visual comfort and the perceived quality of indoor environments.
In historic buildings, where it is often not possible to significantly alter openings and spatial configurations, interventions must be compatible with existing architectural features and aimed at optimizing the passive performance of the building envelope.
Particular attention must be paid to:

  • the distribution of natural light;
  • glare control;
  • natural ventilation;
  • the visual relationship between interior and exterior;
  • the mitigation of summer thermal loads.

Natural lighting contributes both to the physical and mental well-being of occupants and to the reduction of energy consumption for artificial lighting.

Installation of lighting and ventilation systems ->

6. Intervention for humidity and capillary rise

Moisture is one of the main causes of deterioration in historic buildings, manifesting itself as stains, mold, peeling plaster, salt efflorescence, deterioration of mortar and bricks, and decay of wooden structures. The causes of moisture can be continuous or intermittent and often overlap, making it difficult to identify the source of the problem.
Among the most common forms is capillary rising damp, caused by the absorption of water from the ground through porous materials. This phenomenon is exacerbated by the presence of groundwater, standing water, or inadequate waterproofing of the masonry and primarily affects the areas where walls meet the ground.
Water also carries soluble salts which, by crystallizing during evaporation, cause efflorescence, crumbling, and progressive degradation of materials.
The main forms of episodic moisture include:

  • condensation moisture;
  • construction moisture;
  • accidental moisture;
  • rainwater infiltration [Aghemo et al., 1991].

Many of these phenomena can be mitigated by eliminating the root causes of the problem, improving drainage and water disposal systems, or correcting thermal bridges and construction defects.