Urban Heat Islands and Energy Efficiency in Historic Buildings. MIC 2015 Guidelines
MTTM-UHI_MIC-08
Traditional glass does not have good thermal resistance properties. Replacing it with glazing that offers higher thermal resistance improves the energy performance of the building envelope by reducing heat loss through transmission. Fitting new glazing also reduces air infiltration between the glass and the frame. To optimise the work, it is advisable to seal the building envelope.
The measure involves replacing the existing glass with energy-efficient glazing, whilst retaining the original frame. The glass must balance the requirements for thermal insulation and solar control.
Replacing a window results in:
a reduction in air infiltration of up to 82 per cent with a high-seal window.
Replacing the glazing with insulating or solar-collecting units helps to reduce heat loss from the building when technical constraints or aesthetic and historical considerations prevent the replacement of the entire window unit. In section 7, it is of fundamental importance to assess the mechanical strength, state of repair and thermal performance of the existing window frame.
Glazing replacement involves the use of glazing types capable of balancing reduced heat loss with solar gain, based on an assessment of the energy requirements of the building or space. Taking into account the condition, material and dimensional characteristics, and the strength of the frame, one may opt for high-energy-performance glazing such as glass with selective coatings (M.S), insulating glass (M.6), energy-selective glass (M.7), chromogenic glass (M.9) and energy-efficient glass (M.8).
To optimise the renovation, it is advisable to seal any air leaks originating from the joints between the wall cavity and the frame (Fig. 11). Single glazing may be replaced with double glazing provided the frame is made of laminated solid timber, aluminium or thermally broken PVC, and is in a good state of repair with good air and water tightness
Applicability and impact
Efficacy
Applicability
Environmental sustainability
Reversibility
Impact
Quality of redevelopment
Durability
***
****
***
****
****
**
****
Cost and construction logistics
Monetary cost
Construction complexity
Availability (time)
Execution time
Maintenance costs
Regionality
Integrative interventions
Use restriction
****
****
***
****
***
***
***
****
Production process
Degree of innovation
Sustainability
****
****
Formal vulnerability: Mitigations elements in the building – Roofs; Mitigations elements in the building – Facades.
Structural and building services vulnerabilities: Building envelope and its efficiency.
D.lgs 311.2006. Valori limite della trasmittanza termica “U” delle “chiusure trasparenti comprensive degli infissi” (i serramenti completi) e dei vetri.
UNI EN 14351-1; 2010. Finestre e porte – Norma di prodotto, caratteristiche prestazionali.
UNI EN ISO 10077. Prestazione termica di finestre, porte e chiusure oscuranti – Calcolo della trasmittanza termica.