MTTM. UHI-Energy efficiency. MIC 2015 Guidelines.

3. Interventions on the slab. Lower horizontal closures

The opaque ground-level cladding of historic buildings regulates heat exchange with the ground, which is characterised by smaller temperature fluctuations than the external environment.
Work on these components can help to improve both winter heating, by limiting heat loss, and summer cooling, by using the ground as a natural heat sink.
Particular attention must be paid to problems of rising damp and condensation, which are very common in historic buildings.
For this reason, it is generally advisable to install waterproofing systems and, where compatible with the thermo-hygrometric behaviour of the building envelope, vapour barriers and breathable materials.

Passive heating

Improvements to the winter performance of ground-level openings are achieved primarily by incorporating insulating layers.
As it is not possible to make changes to the foundations or the soil structure, interventions are generally limited to internal surfaces or floor slabs above unheated basement areas.
The main methods of intervention are:

  • insulation on the upper surface of the floor slab above unheated rooms;
  • insulation on the underside of the floor slab in contact with the ground.

In both cases, compatibility with the dimensional and height requirements of the rooms must be verified.
Where thickness represents a design constraint, high-performance, low-thickness materials may be used, such as heat-reflective or vacuum insulation.

Passive cooling

Ground-level closures can contribute to passive cooling by utilising the relatively stable temperature of the ground, which at greater depths tends to approach the average annual temperature of the outside air.
Geothermal cooling can occur:

  • directly, by dissipating heat into the ground through the mass of the structures;
  • indirectly, via heat transfer fluids circulating in underground pipes.

Direct systems are more effective in underground or basement spaces and require the absence of thermal insulation between the building and the ground.
Indirect systems, on the other hand, generally use air channelled through underground pipes to cool or preheat rooms. These solutions can operate:

  • in an open-loop system, which also provides ventilation for the rooms;
  • in a closed-loop system, which is limited to heat exchange.

In historic buildings, the installation of geothermal systems requires a careful assessment of compatibility, reversibility and impact on existing structures

Interventions

In.14. Insulation on the extrados of the slab in correspondence with unheated rooms

The work involves installing a continuous layer of insulation on the upper surface of the floor slab that separates heated rooms from basement areas or unheated spaces.
This solution improves thermal insulation and reduces thermal bridges, particularly when combined with natural ventilation systems in the rooms below. As an alternative to insulation panels, thermal insulation plasters compatible with the historic building may be used

In.15. Insulation on the underside of the ground floor

In the case of floors resting directly on the ground, insulation can only be applied to the interior side. This work reduces heat loss but does not completely eliminate structural thermal bridges.
It is also necessary to incorporate appropriate measures against rising damp, such as waterproofing and vapour barriers. Where the spaces are inhabited, the insulation system must ensure adequate mechanical strength and compatibility with surface finishes.
The work involves the automation of window and door opening systems to allow for controlled ventilation, even in situations where manual opening is not possible, such as in public buildings or for scheduled night-time ventilation.