MTTM_Sisma_1-3_Inserimento_cordoli_muratura_armata

MTTM. Earthquake

1. Interventions to reduce connection gaps
1.3 Insertion of curbs in reinforced masonry

MTTM-HEA-1.3

Description

The reinforced masonry parapet is a reinforcement solution designed to reduce weaknesses in the connections between walls and to improve the interaction between the masonry and the roof structure, whilst maintaining a high degree of compatibility with traditional construction techniques. The work involves constructing a top-of-wall beam using masonry of suitable quality, generally solid bricks, into which metal reinforcement or, in specific cases, composite materials are inserted, and which is securely fixed in place using mortar or concrete. If correctly designed and connected to the existing masonry, the coping helps to improve the structural continuity of the building, facilitating the transmission of horizontal forces to the load-bearing walls, limiting out-of-plane overturning mechanisms and enhancing the box-like behaviour of the structure during seismic events. The connection to the underlying masonry is generally achieved through adhesion, interlocking between the masonry elements and friction; should the top course of masonry show signs of deterioration or poor cohesion, prior consolidation work may be necessary, for example by means of injections of compatible mortar. In historic buildings, reinforced masonry kerbs are often a preferable solution to reinforced concrete kerbs, as they offer better mechanical and material compatibility with the existing masonry and limit the introduction of elements characterised by high rigidity.

Advantages

The reinforced masonry kerb improves the connection between the walls and the roof structure, promoting the building’s box-like behaviour during seismic events. Thanks to its good mechanical and material compatibility with historic masonry, it is a particularly suitable solution for interventions on cultural heritage sites, minimising the introduction of excessively rigid elements. The intervention also contributes to a more uniform distribution of horizontal forces and, in many cases, may prove less invasive than other types of coping.

Disadvantages and limitations of applicability

The effectiveness of a reinforced masonry kerb depends on the quality of the existing masonry and on the work being carried out correctly. Where the masonry is poorly bonded or has low strength, the work may be less effective and requires particular attention to be paid to the design of the connections with the existing structure. Furthermore, where high load-bearing capacities or particularly high levels of stiffness are required, this solution may not be the most appropriate option. The use of inclined reinforced dowels should also be limited to cases where it is strictly necessary and supported by specific design checks.

Synergies, interactions and opportunities for complementary interventions

Where masonry is deteriorated or lacks cohesion, it is advisable to carry out preliminary consolidation of the top section of the wall, for example by injecting compatible mortar or by other measures consistent with the building’s structural characteristics. Where the roof exerts significant horizontal thrusts and the design of the parapet results in excessively large cross-sections, it is generally preferable to supplement the works with thrust-containment systems, such as metal chains, thereby reducing the stresses acting on the parapet and improving the overall performance of the structure.

Assessment against the criteria

Applicability and impact

Efficacy
Applicability
Environmental sustainability
Reversibility
Impact
Durability

****
***
*****
*
****
****

Cost and construction logistics

Monetary cost
Construction complexity
Availability (time)
Execution time
Maintenance costs
Regionality
Integrative interventions
Use restriction

***
***
****
***
*****
****
****
***

Production process

Degree of innovation
Sustainability

***
****

Relationship with the indicators of the Risk Analysis Model

Structural vulnerability: Links between structural elements. Roofs.

References

Borri, A., & De Maria, A. (2018). Masonry strengthening with composite materials. In: Strengthening and Retrofitting of Existing Structures.
Cattari, S., Lagomarsino, S., Bosiljkov, V., D’Ayala, D., et al. (2015). The guidelines for the seismic performance assessment of cultural heritage masonry structures by CEN TC346. Bulletin of Earthquake Engineering, 13, 927–965.
Consiglio Superiore dei Lavori Pubblici (2019). Circolare 21 gennaio 2019, n. 7 C.S.LL.PP. – Istruzioni per l’applicazione dell’Aggiornamento delle “Norme Tecniche per le Costruzioni” D.M. 17 gennaio 2018.
Doglioni, F., Moretti, A., & Petrini, V. (1994). Le chiese e il terremoto. LINT, Trieste.
ICOMOS (2003). Principles for the Analysis, Conservation and Structural Restoration of Architectural Heritage.
Lagomarsino, S., & Cattari, S. (2015). PERPETUATE Guidelines for Seismic Performance-Based Assessment of Cultural Heritage Masonry Structures. Bulletin of Earthquake Engineering, 13, 13–47.
Ministero dei Beni e delle Attività Culturali e del Turismo (2011). Linee guida per la valutazione e riduzione del rischio sismico del patrimonio culturale con riferimento alle Norme Tecniche per le Costruzioni di cui al D.M. 14 gennaio 2008.
Ministero delle Infrastrutture e dei Trasporti (2018). Aggiornamento delle Norme Tecniche per le Costruzioni. D.M. 17 gennaio 2018.
Roca, P., Cervera, M., Gariup, G., & Pelà, L. (2010). Structural Analysis of Masonry Historical Constructions: Classical and Advanced Approaches. Archives of Computational Methods in Engineering, 17(3), 299–325.
Tomaževič, M. (1999). Earthquake-Resistant Design of Masonry Buildings. Imperial College Press.