MTTM_MIC2015_In_12_pellicole_isolanti_captanti

Urban Heat Islands and Energy Efficiency in Historic Buildings.
MIC 2015 Guidelines

4. Application of films and screens
In.12. Application of insulating or absorbing films to glass

MTTM-UHI_MIC-12

Description

This measure involves the application of special insulating or selective films to improve the thermal resistance of the glass and reduce heat loss through the transparent building envelope.
A low-emissivity film—consisting of a vapor-deposited aluminum coating—enhances the thermal performance of the glass by reducing heat loss via radiation. The metallic coating reflects infrared radiation back toward the interior, limiting heat dissipation and maintaining thermal comfort for the occupants.
The film must be applied to the innermost surface of the glazing unit.

Advantages

Applying a special film is a procedure that leaves the original aesthetic appearance of a window or door unit unchanged, as the film is transparent.
These state-of-the-art films reduce heat loss to the outside by up to 30%, while in the summer months, they cut down solar heat gain by up to 70% and glare by up to 80%.

Disadvantages and limitations of applicability

An assessment of the existing window’s condition is necessary to determine the technical feasibility and economic viability of the intervention.
Based on current research, the energy benefit provided is too limited to make the operation cost-effective, as heat loss from the interior represents only one component of a building’s total heat loss.

Synergies, interactions and opportunities for complementary interventions

The economic viability of the intervention increases when double glazing—consisting of float glass—is present, along with frames that offer good thermal insulation and an absence of air infiltration at the junctions between the glass and the frame, between fixed and operable frame components, and between the window unit and the wall opening.
It may be necessary to combine this with measures to insulate and seal air leaks around the frame (see intervention no. 11).
For buildings of historical or artistic significance, this can serve as a sound compromise solution, provided it is paired with the sealing of air leaks. The application of the film must be carried out by specialized technical personnel; improper installation could lead to issues regarding the adhesion and uniformity of the adhesive, the chemical-physical compatibility between the film and the adhesive, and the overall durability of the film. Maintenance must be performed using techniques and products that are compatible with the chemical, physical, and mechanical resistance of the material.

Assessment against the criteria

Applicability and impact

Efficacy
Applicability
Environmental sustainability
Reversibility
Impact
Quality of redevelopment
Durability

***
****
***
*****
*****
**
***

Cost and construction logistics

Monetary cost
Construction complexity
Availability (time)
Execution time
Maintenance costs
Regionality
Integrative interventions
Use restriction

***
***
****
****
**
***
**
****

Production process

Degree of innovation
Sustainability

*****
*****

Relationship with the indicators of the Risk Analysis Model

Formal vulnerability: Mitigations elements in the building – Roofs; Mitigations elements in the building – Facades.
Structural and building services vulnerabilities: Building envelope and its efficiency.

Riferimenti

D.lgs 311.2006. Valori limite della trasmittanza termica “U” delle “chiusure trasparenti comprensive degli infissi” (i serramenti completi) e dei vetri.
UNI EN 14351-1; 2010. Finestre e porte – Norma di prodotto, caratteristiche prestazionali.
UNI EN ISO 10077. Prestazione termica di finestre, porte e chiusure oscuranti – Calcolo della trasmittanza termica.