MTTM_MIC2015_In_10_Inserimento_seconda_lastra_vetro

Urban Heat Islands and Energy Efficiency in Historic Buildings.
MIC 2015 Guidelines

2. Replacement of windows and installation of glass
In.10. Installation of second glass door on the inside of the mobile doors

MTTM-UHI_MIC-10

Description

The measure involves the installation of a fixed or openable secondary glazing unit within the existing wall cavity on the inner side of the movable sash, fitted with suitable glazing beads, to improve the window’s thermal insulation performance and reduce air infiltration. The secondary glazing, which may be removable on a seasonal basis, consists of a detachable and openable system, framed within an aluminium or stainless steel profile, which creates an air cavity to increase thermal inertia. It can be fitted on the inside or the outside: external fitting is the most common due to cost considerations and ease of installation; however, internal installation is more efficient as it minimises heat loss, improves airtightness and prevents condensation from forming.

Advantages

The work involves: a partial reduction in the thermal load associated with the windows and doors; a significant reduction in air infiltration thanks to high-seal windows and doors.
The energy savings are lower than those achieved by replacing the glazing or the entire window unit, but this approach involves fewer compatibility issues and lower installation costs. It may reduce the amount of light entering the room and affect the user’s visual comfort: it will be necessary to choose glazing with a light transmission index greater than 0.80.

Disadvantages and limitations of applicability

Fitting a secondary pane or a double-glazed window helps to reduce heat loss from the building when technical constraints or aesthetic and historical considerations prevent the replacement of the In.8 glazing or the entire In.7 window unit. It is, in any case, a modification that alters the original appearance, albeit to a limited extent.
It will be necessary to properly assess the mechanical strength of the window frame and the existing wall cavity to ensure they can support the weight of the new glazing.
An openable secondary glazing unit is light and easy to handle: this implies that it may be prone to warping, is fragile and has a reduced lifespan, as well as potentially causing problems with opening and handling.
The presence of a fixed secondary glazing unit may affect the natural ventilation of a room.
Installation is advisable in the case of windows with single or double glazing lacking thermal control, where the frames are in good condition and there is significant air infiltration. Tests must be carried out to verify the window’s ability to support the weight of the new structure without damage; it is also important that the thickness of the new structure does not prevent the sash from rotating.

Synergies, interactions and opportunities for complementary interventions

To improve energy efficiency, it is advisable to use double glazing with a cavity filled with air or an inert gas. The outer pane may be made of low-emissivity or selective M.5 glass. It is important to ensure that the dimensions and materials are compatible with the wall opening, the façade cladding and any sun-shading systems. It is necessary to check that the outer pane adheres perfectly to the window frame: the perimeter must be hermetically sealed; In.11 gaskets may also be fitted.

Assessment against the criteria

Applicability and impact

Efficacy
Applicability
Environmental sustainability
Reversibility
Impact
Quality of redevelopment
Durability

***
****
***
*****
****
**
****

Cost and construction logistics

Monetary cost
Construction complexity
Availability (time)
Execution time
Maintenance costs
Regionality
Integrative interventions
Use restriction

***
***
***
***
****
***
***
****

Production process

Degree of innovation
Sustainability

****
****

Relationship with the indicators of the Risk Analysis Model

Formal vulnerability: Mitigations elements in the building – Roofs; Mitigations elements in the building – Facades.
Structural and building services vulnerabilities: Building envelope and its efficiency

References

D.lgs 311.2006. Valori limite della trasmittanza termica “U” delle “chiusure trasparenti comprensive degli infissi” (i serramenti completi) e dei vetri.
UNI EN 14351-1; 2010. Finestre e porte – Norma di prodotto, caratteristiche prestazionali.
UNI EN ISO 10077. Prestazione termica di finestre, porte e chiusure oscuranti – Calcolo della trasmittanza termica.