MTTM-UHI_MIC-04
The external insulation of the building, applied uniformly and without interruption across the entire surface (external thermal insulation system), creates a continuous barrier against heat transfer and controls the build-up of moisture within the wall. It consists of applying insulation panels to the entire external surface of the building, which are then protected by a protective finishing layer made from specialised plasters.
When refurbishing historic buildings, to ensure the reversibility of the work, it is good practice to avoid gluing the panels in place, opting instead for the use of approved wall plugs or profiles, depending on the coplanarity of the wall substrate. The choice of insulation must be compatible with the permeability and breathability of the wall system: in the case of solid-wall buildings, the use of natural organic fibrous materials (M.4) with good hygroscopic properties is recommended.
As external insulation allows the masonry to act as a thermal mass, this solution is optimised for environments where the heating system operates continuously.
The main advantages lie in the ability to clad the external surface uniformly, ensuring effective control of thermal bridges in buildings without protruding structural elements, and minimising heat loss and the build-up of surface condensation, damp patches or mould inside the rooms.
Furthermore, as the external insulation increases the wall’s thickness towards the outside, it does not take up space from the internal rooms, as is the case with the In.6 internal lining insulation.
Finally, the use of external insulation allows the thermal inertia of the walls on the inside of the building to be utilised to stabilise comfort conditions and increase radiant heating, thereby optimising the operation of the air-conditioning system. The thermal mass can then be used, during the summer, to absorb and dissipate excess heat, improving the building’s passive cooling.
External insulation involves altering the building’s external elevations; it may therefore only be carried out if it is compatible with the aesthetic and technical characteristics of the façade.
The work may not be cost-effective if the building’s form features a significant number of geometric discontinuities that cannot be interrupted or covered by the insulating layer (for example, where there are balconies or loggias).
The main disadvantage of external insulation is the alteration of the external elevations; furthermore, it has a significant impact on the building’s hygrometric behaviour.
External insulation of vertical openings is most effective at reducing thermal bridges when combined with insulation of the roof (In.I -2-3) and the ground connection (In.14-15), and with the replacement, upgrading or refurbishment of window and door frames (In.7-8); however, to prevent condensation, it is advisable to ensure a certain degree of ventilation within the system.
Applicability and impact
Efficacy
Applicability
Environmental sustainability
Reversibility
Impact
Quality of redevelopment
Durability
*****
**
***
*
*
**
****
Cost and construction logistics
Monetary cost
Construction complexity
Availability (time)
Execution time
Maintenance costs
Regionality
Integrative interventions
Use restriction
**
**
***
**
***
***
**
***
Production process
Degree of innovation
Sustainability
**
***
Formal vulnerability: Mitigations elements in the building – Roofs. Building albedo – Facades.
Structural and building services vulnerabilities: Building envelope and its efficiency.
UNI EN ISO 13788:2003. Hygrometric performance of building components and elements. Italian National Standardisation Body. Milan.
UNI EN ISO 10211:2008. Thermal bridges in building construction. Italian National Standardisation Body. Milan.
Ministerial Decree of 26 January 2010. Amendment to the Decree of 11 March 2008 on the energy retrofitting of buildings