MTTM-UHI_MIC-03
Insulation on the underside of the roof improves the insulation of the building envelope when it is not possible to work on the extrados. Furthermore, it is good practice to choose high-performance insulation materials even with thin layers, such as M.I. heat-reflecting or M.2 vacuum insulation. Installation can involve the use of self-supporting panels, fixed to the underside of the attic or the load-bearing structure of the sloping roof using dry anchors. If the existing volumes allow it, the insulation can be spaced away from the attic, creating an internal ventilated cavity that reduces condensation, improves summer cooling, and accommodates the installation of systems. For insulation with panels inserted directly into the existing attic, it is advisable to choose materials with low thermal conductivity and good vapor permeability. In insulated and ventilated false ceilings, it is also possible to use hygroscopic materials, as the air cavity prevents the formation of interstitial and superficial condensation.
Due to its lower efficiency compared to external insulation, this method is preferred when the external roofing cannot be altered.
This method allows for the creation of a false ceiling to house the systems, which can be very cost-effective when combined with the overall system.
Insulation on the underside is quick and easy to install and can be applied selectively and staggered, although this method increases the risk of condensation as it significantly disrupts the thermal properties of the envelope.
In the case of pitched or skeleton roofs, the system protects the structure from thermal shock, helping to increase its lifespan.
Since the intervention reduces the usable volume of the rooms, it is necessary to ensure compliance with the height restrictions set by regulations.
Insulation on the underside of the roof alters the appearance of the attic; it can only be implemented if it is compatible with the aesthetic and technological characteristics of the rooms below the roof, or when the attic must not be left exposed.
Since internal insulation excludes the use of the roof’s load-bearing structure as thermal mass, it is preferable for rooms with intermittent use of the heating system or for non-habitable spaces.
Compared to insulation on the underside, insulation on the underside presents greater discontinuity and limits the use of the roof’s load-bearing structures as thermal mass.
It cannot eliminate structural thermal bridges, which can lead to interstitial condensation, damp stains, or mold.
It reduces the usable internal volume, especially if a cavity is created.
Internal insulation requires lining all boundary surfaces, including vertical In.6 closures; furthermore, in the case of complex internal morphologies, it can be integrated with the use of thermal insulating plasters, in a manner similar to the external vertical In.5 thermal insulating plasters.
Applicability and impact
Efficacy
Applicability
Environmental sustainability
Reversibility
Impact
Quality of redevelopment
Durability
***
***
***
***
****
**
****
Cost and construction logistics
Monetary cost
Construction complexity
Availability (time)
Execution time
Maintenance costs
Regionality
Integrative interventions
Use restriction
***
****
***
***
***
***
***
***
Production process
Degree of innovation
Sustainability
***
****
Formal vulnerability: Mitigations elements in the building – Roofs.
Structural and building services vulnerabilities: Building envelope and its efficiency; Roof constructions materials and their thermal resilience.
UNI EN ISO 13788:2003. Hygrometric performance of building components and elements. Italian National Standardisation Body. Milan.
UNI EN ISO 10211:2008. Thermal bridges in building construction. Italian National Standardisation Body. Milan.
Ministerial Decree of 26 January 2010 (Italy). Amendment to the Decree of 11 March 2008 on the energy retrofitting of buildings.