{"id":16901,"date":"2026-11-13T14:23:16","date_gmt":"2026-11-13T13:23:16","guid":{"rendered":"https:\/\/www.corila.it\/?page_id=16901"},"modified":"2026-11-13T14:23:55","modified_gmt":"2026-11-13T13:23:55","slug":"mttm_sisma_4-1_collegamento_capochiave_metallico","status":"publish","type":"page","link":"https:\/\/www.corila.it\/en\/mttm_sisma_4-1_collegamento_capochiave_metallico\/","title":{"rendered":"MTTM_Sisma_4-1_Collegamento_capochiave_metallico"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: right;\"><a href=\"https:\/\/www.corila.it\/en\/metodologie-tecnologie-tecniche-e-materiali-per-ladeguamento-e-lefficientamento-di-edifici-e-siti-storici\/\">&lt;- back to home<\/a><\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16885&#8243; img_size=&#8221;800&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4>MTTM. Earthquake<\/h4>\n<h5>4. Interventions aimed at reducing thrusts and excess deformability in the roofs<br \/>\n4.1 Connection with metal key cap<\/h5>\n<p>MTTM-HEA-4.1[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Description<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The use of metal tie-ins is a technique designed to improve the connection between the roof framing elements and the perimeter walls, thereby limiting relative movements. In particular, it prevents translational movement or loss of support during seismic activity. The work can be carried out using metal bars, pins or tie rods connected to the timber elements of the roof and anchored to the masonry via external tie-ins, generally consisting of plates or other metal components capable of distributing the forces over a sufficiently large area of the wall. The system allows the roof and the top section of the masonry to be integrated, promoting a more unified behaviour of the building structure and contributing to the stabilisation of the upper parts of the walls, which are particularly vulnerable to out-of-plane forces. This connection can prove particularly useful in historic buildings with timber roofs, where the preservation of the existing roof structure is often a priority. However, the design must carefully consider the geometry and condition of the masonry, the position of the anchors, the load-bearing capacity of the timber elements, and the distribution of stresses introduced by the lintel.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Advantages<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]This method is generally effective in counteracting relative movements between the roof structure and the masonry and in improving the connection between the various parts of the structural system. It is characterised by minimal invasiveness, a small increase in mass and good compatibility with the preservation of existing timber structures. The use of mechanically connected metal devices also allows for localised interventions that can be inspected and, in many cases, are partially reversible.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Disadvantages and limitations of applicability<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The effectiveness of the system depends to a significant extent on the quality and condition of the masonry in the anchorage area. Masonry that is unstable, degraded or consists of multiple courses with poor bonding may not be able to properly absorb the forces transmitted by the keystone and may require preliminary consolidation work. Insufficient dimensioning or an inappropriate distribution of pressures may lead to localised crushing, cracking or detachment of the masonry. In buildings of historical interest, the visual impact of external metal elements and their compatibility with decorated surfaces or features of architectural merit must also be assessed.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Synergies, interactions and opportunities for complementary interventions<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]It may be advisable to combine the use of key-head connectors with the local reinforcement of the masonry affected by the anchoring, the improvement of connections between the timber framework elements and, where necessary, the strengthening of the connections between the roof and the top-most masonry. Where roofs are characterised by thrust, the key-head connection must be regarded as part of a wider system and not as a substitute for devices specifically designed to counteract horizontal thrusts. It may also be necessary to verify the capacity of the timber elements to transfer the anticipated loads to the anchors without causing local crushing, cracking or failure.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Assessment against the criteria<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Applicability and impact[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Efficacy<br \/>\nApplicability<br \/>\nEnvironmental sustainability<br \/>\nReversibility<br \/>\nImpact<br \/>\nDurability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n****<br \/>\n*****<br \/>\n***<br \/>\n***<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Cost and construction logistics[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Monetary cost<br \/>\nConstruction complexity<br \/>\nAvailability (time)<br \/>\nExecution time<br \/>\nMaintenance costs<br \/>\nRegionality<br \/>\nIntegrative interventions<br \/>\nUse restriction[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">****<br \/>\n****<br \/>\n****<br \/>\n***<br \/>\n****<br \/>\n****<br \/>\n*****<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Production process[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Degree of innovation<br \/>\nSustainability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Relationship with the indicators of the Risk Analysis Model<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]<em>Structural vulnerability<\/em>: Roofs[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Riferimenti<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Ministero per i Beni e le Attivit\u00e0 Culturali (2011). <em>Direttiva del Presidente del Consiglio dei ministri 9 febbraio 2011. Valutazione e riduzione del rischio sismico del patrimonio culturale con riferimento alle Norme tecniche per le costruzioni<\/em>.<\/p>\n<p>Giuffr\u00e8, A. (a cura di) (1993). <em>Sicurezza e conservazione dei centri storici. Il caso Ortigia. Codice di pratica per gli interventi antisismici nel centro storico<\/em>. Laterza, Roma-Bari.<\/p>\n<p>Doglioni, F., Mazzotti, P. (a cura di) (2007). <em>Codice di pratica per gli interventi di miglioramento sismico nel restauro del patrimonio architettonico<\/em>. Regione Marche, Ancona.<\/p>\n<p>Roca, P., Cervera, M., Gariup, G., Pel\u00e0, L. (2010). <em>Structural Analysis of Masonry Historical Constructions. Classical and Advanced Approaches<\/em>. Archives of Computational Methods in Engineering, 17(3), 299\u2013325<\/p>\n<p>Caliendo, G., Canu, A., Cinieri, V., D\u2019Andrea, M., Fersini, M., Meli, C., Orazi, D., Serpe, E., Zamperini, E. (2015). <em>Catene metalliche negli edifici storici in muratura. Diffusione, tipi e usi in diverse aree italiane<\/em>. Scienza e Beni Culturali, XXXI, 683\u2013697.[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text] &lt;- back to home [\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16885&#8243; img_size=&#8221;800&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] MTTM&#8230;.<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16901","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16901","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/comments?post=16901"}],"version-history":[{"count":4,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16901\/revisions"}],"predecessor-version":[{"id":16922,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16901\/revisions\/16922"}],"wp:attachment":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/media?parent=16901"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}