{"id":16754,"date":"2026-10-08T16:14:47","date_gmt":"2026-10-08T14:14:47","guid":{"rendered":"https:\/\/www.corila.it\/?page_id=16754"},"modified":"2026-10-08T16:14:47","modified_gmt":"2026-10-08T14:14:47","slug":"mttm_mic2015_in_08_sostituzione_vetri_telaio","status":"publish","type":"page","link":"https:\/\/www.corila.it\/en\/mttm_mic2015_in_08_sostituzione_vetri_telaio\/","title":{"rendered":"MTTM_MIC2015_In_08_Sostituzione_vetri_telaio"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: right;\"><a href=\"https:\/\/www.corila.it\/en\/metodologie-tecnologie-tecniche-e-materiali-per-ladeguamento-e-lefficientamento-di-edifici-e-siti-storici\/\">&lt;- torna a home<\/a><\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16147&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<strong>Urban Heat Islands and Energy Efficiency in Historic Buildings. MIC 2015 Guidelines<\/strong><\/p>\n<h5>2. Replacement of windows and installation of glass<br \/>\nIn.08. <strong>Replacement of glass with insulating or absorbing models on existing frames<\/strong><\/h5>\n<p>MTTM-UHI_MIC-08[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Description<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Traditional glass does not have good thermal resistance properties. Replacing it with glazing that offers higher thermal resistance improves the energy performance of the building envelope by reducing heat loss through transmission. Fitting new glazing also reduces air infiltration between the glass and the frame. To optimise the work, it is advisable to seal the building envelope.<br \/>\nThe measure involves replacing the existing glass with energy-efficient glazing, whilst retaining the original frame. The glass must balance the requirements for thermal insulation and solar control.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Advantages<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Replacing a window results in:<\/p>\n<ul>\n<li>a reduction in the thermal load associated with the windows of between 50 per cent and 1.85 per cent, depending on the type of glazing being replaced;<\/li>\n<li>a reduction in solar heat gain through the windows of between 27 per cent and 145 per cent when using low-emissivity or selective glazing;<\/li>\n<\/ul>\n<p>a reduction in air infiltration of up to 82 per cent with a high-seal window.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Disadvantages and limitations of applicability<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Replacing the glazing with insulating or solar-collecting units helps to reduce heat loss from the building when technical constraints or aesthetic and historical considerations prevent the replacement of the entire window unit. In section 7, it is of fundamental importance to assess the mechanical strength, state of repair and thermal performance of the existing window frame.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Synergies, interactions and opportunities for complementary interventions<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Glazing replacement involves the use of glazing types capable of balancing reduced heat loss with solar gain, based on an assessment of the energy requirements of the building or space. Taking into account the condition, material and dimensional characteristics, and the strength of the frame, one may opt for high-energy-performance glazing such as glass with selective coatings (M.S), insulating glass (M.6), energy-selective glass (M.7), chromogenic glass (M.9) and energy-efficient glass (M.8).<br \/>\nTo optimise the renovation, it is advisable to seal any air leaks originating from the joints between the wall cavity and the frame (Fig. 11). Single glazing may be replaced with double glazing provided the frame is made of laminated solid timber, aluminium or thermally broken PVC, and is in a good state of repair with good air and water tightness[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Assessment against the criteria<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Applicability and impact[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Efficacy<br \/>\nApplicability<br \/>\nEnvironmental sustainability<br \/>\nReversibility<br \/>\nImpact<br \/>\nQuality of redevelopment<br \/>\nDurability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n****<br \/>\n***<br \/>\n****<br \/>\n****<br \/>\n**<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Cost and construction logistics[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Monetary cost<br \/>\nConstruction complexity<br \/>\nAvailability (time)<br \/>\nExecution time<br \/>\nMaintenance costs<br \/>\nRegionality<br \/>\nIntegrative interventions<br \/>\nUse restriction[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]****<br \/>\n****<br \/>\n***<br \/>\n****<br \/>\n***<br \/>\n***<br \/>\n***<br \/>\n****[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Production process[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Degree of innovation<br \/>\nSustainability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">****<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Relationship with the indicators of the Risk Analysis Model<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]<em>Formal vulnerability<\/em>: Mitigations elements in the building \u2013 Roofs; Mitigations elements in the building &#8211; Facades.<br \/>\n<em>Structural and building services vulnerabilities<\/em>: Building envelope and its efficiency.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>References<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]D.lgs 311.2006. Valori limite della trasmittanza termica \u201cU\u201d delle \u201cchiusure trasparenti comprensive degli infissi\u201d (i serramenti completi) e dei vetri.<br \/>\nUNI EN 14351-1; 2010. Finestre e porte \u2013 Norma di prodotto, caratteristiche prestazionali.<br \/>\nUNI EN ISO 10077. Prestazione termica di finestre, porte e chiusure oscuranti \u2013 Calcolo della trasmittanza termica.[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text] &lt;- torna a home [\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16147&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]Urban Heat&#8230;<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16754","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16754","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/comments?post=16754"}],"version-history":[{"count":2,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16754\/revisions"}],"predecessor-version":[{"id":16758,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16754\/revisions\/16758"}],"wp:attachment":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/media?parent=16754"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}