{"id":16737,"date":"2026-10-05T13:36:23","date_gmt":"2026-10-05T11:36:23","guid":{"rendered":"https:\/\/www.corila.it\/?page_id=16737"},"modified":"2026-10-05T13:41:02","modified_gmt":"2026-10-05T11:41:02","slug":"mttm_sisma_2-3_placcaggi_sottarco","status":"publish","type":"page","link":"https:\/\/www.corila.it\/en\/mttm_sisma_2-3_placcaggi_sottarco\/","title":{"rendered":"MTTM_Sisma_2-3_Placcaggi_sottarco"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: right;\"><a href=\"https:\/\/www.corila.it\/en\/metodologie-tecnologie-tecniche-e-materiali-per-ladeguamento-e-lefficientamento-di-edifici-e-siti-storici\/\">&lt;- back to<\/a><a href=\"https:\/\/www.corila.it\/en\/metodologie-tecnologie-tecniche-e-materiali-per-ladeguamento-e-lefficientamento-di-edifici-e-siti-storici\/\"> home<\/a><\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16702&#8243; img_size=&#8221;800&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4>MTTM. Earthquake<\/h4>\n<h5>2. Interventions aimed at reducing the thrust of arches and vaults and at their consolidation<br \/>\n2.3. Plating with composite material bands and creation of an under-arch<\/h5>\n<p>MTTM-HEA-2.3[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Description<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Composite material sheeting is a reinforcement technique designed to increase the load-bearing capacity of arches and vaults by applying bands or reinforcement systems with high mechanical strength and low self-weight. In historic buildings, these interventions are generally carried out on the extrados, where they are less invasive from an architectural standpoint and more compatible with conservation requirements. The arrangement of the bands must be determined based on a thorough structural analysis capable of identifying stress paths and verifying the effectiveness of the reinforcement. Reinforcement on the intrados may be used when combined with the construction of a sub-arch\u2014made of masonry, laminated wood, or other compatible materials\u2014capable of counteracting the thrusts generated by the vaulted structure. Alternatively, these thrusts can be counterbalanced using point anchorage systems distributed along the intrados. This latter solution is generally more invasive and must be evaluated with particular care in buildings of historical significance. Reducing the permanent loads on the extrados\u2014through the use of lightweight fillers or other techniques\u2014represents another possible course of action. However, this solution requires specific design analyses, as it alters the pressure distribution within the vault and may increase its sensitivity to accidental loads. The design must also carefully evaluate the compatibility of the materials used with the structural and conservation characteristics of the historic structure.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Advantages<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Composite materials make it possible to carry out repairs that are lightweight and highly resistant to mechanical stress, thereby limiting the increase in structural mass. Applying them to the upper surface generally reduces the visual impact of the repair and, in many cases, preserves good accessibility for inspection. When properly designed, these systems can increase the load-bearing capacity of arches and vaults without significantly altering the structure\u2019s geometry.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Disadvantages and limitations of applicability<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The use of composite materials requires special attention to compatibility with historic masonry. The use of resins can alter the local breathability of the masonry, a particularly sensitive issue when decorative or frescoed surfaces are present. Furthermore, the long-term performance of reinforcement systems depends on the durability of the composite materials and the adhesive products used. The complete reversibility of the intervention is generally not guaranteed, since some of the resin may penetrate the surface layer of the masonry.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Synergies, interactions and opportunities for complementary interventions<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]When the cladding is installed on the underside of the vault, it is generally advisable to combine it with a sub-arch or other structural systems capable of effectively counteracting the thrusts of the vault. If there is damage or deterioration in the masonry, repair and reinforcement work must be carried out beforehand to restore structural continuity through the injection of compatible mortar, the insertion of wedges, or other localized interventions. If there are significant deformations of the arch or vault, cladding alone may be insufficient and must be supplemented with additional consolidation work, such as sub-arches or other appropriately designed reinforcement structures.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Assessment against the criteria<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Applicability and impact[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Efficacy<br \/>\nApplicability<br \/>\nEnvironmental sustainability<br \/>\nReversibility<br \/>\nImpact<br \/>\nDurability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">****<br \/>\n****<br \/>\n*****<br \/>\n****<br \/>\n****<br \/>\n***<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Cost and construction logistics[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Monetary cost<br \/>\nConstruction complexity<br \/>\nAvailability (time)<br \/>\nExecution time<br \/>\nMaintenance costs<br \/>\nRegionality<br \/>\nIntegrative interventions<br \/>\nUse restriction[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">****<br \/>\n****<br \/>\n****<br \/>\n****<br \/>\n***<br \/>\n****<br \/>\n**<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Production process[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Degree of innovation<br \/>\nSustainability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Relationship with the indicators of the Risk Analysis Model<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]<em>Structural vulnerability<\/em>: Arch and vault.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>References<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Doglioni, F., Moretti, A., &amp; Petrini, V. (1994). Le chiese e il terremoto. LINT, Trieste.<br \/>\nMinistero della Cultura (2011). Linee guida per la valutazione e riduzione del rischio sismico del patrimonio culturale.<br \/>\nMinistero delle Infrastrutture e dei Trasporti (2018). Aggiornamento delle Norme Tecniche per le Costruzioni. D.M. 17 gennaio 2018.<br \/>\nConsiglio Superiore dei Lavori Pubblici (2019). Circolare n. 7 C.S.LL.PP.<br \/>\nICOMOS (2003). Principles for the Analysis, Conservation and Structural Restoration of Architectural Heritage.<br \/>\nLagomarsino, S., &amp; Cattari, S. (2015). PERPETUATE Guidelines for Seismic Performance-Based Assessment of Cultural Heritage Masonry Structures.<br \/>\nRoca, P., Cervera, M., Gariup, G., &amp; Pel\u00e0, L. (2010). Structural Analysis of Masonry Historical Constructions.<br \/>\nToma\u017eevi\u010d, M. (1999). Earthquake-Resistant Design of Masonry Buildings.<br \/>\nValluzzi, M. R. (2007). Criteri e tecniche di consolidamento delle strutture murarie storiche.[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text] &lt;- back to home [\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16702&#8243; img_size=&#8221;800&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] MTTM&#8230;.<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16737","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16737","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/comments?post=16737"}],"version-history":[{"count":3,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16737\/revisions"}],"predecessor-version":[{"id":16743,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16737\/revisions\/16743"}],"wp:attachment":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/media?parent=16737"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}