{"id":16575,"date":"2026-09-28T13:22:37","date_gmt":"2026-09-28T11:22:37","guid":{"rendered":"https:\/\/www.corila.it\/?page_id=16575"},"modified":"2026-09-28T13:22:37","modified_gmt":"2026-09-28T11:22:37","slug":"mttm_sisma_1-2_inserimento_cerchiature","status":"publish","type":"page","link":"https:\/\/www.corila.it\/en\/mttm_sisma_1-2_inserimento_cerchiature\/","title":{"rendered":"MTTM_Sisma_1-2_Inserimento_cerchiature"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: right;\"><a href=\"https:\/\/www.corila.it\/en\/metodologie-tecnologie-tecniche-e-materiali-per-ladeguamento-e-lefficientamento-di-edifici-e-siti-storici\/\">&lt;- torna a home<\/a><\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16560&#8243; img_size=&#8221;800&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4>MTTM. Earthquake<\/h4>\n<h5>1. Interventions to reduce connection gaps<br \/>\n1.2 Inserting hoops<\/h5>\n<p>MTTM-HEA-1.2[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Description<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The installation of hoops is a localised intervention aimed at reducing deficiencies in the structural connections of masonry buildings and limiting the activation of local mechanisms during seismic events. The intervention generally involves the construction of confinement systems using metal frames or profiles suitably connected to the masonry, capable of redistributing stresses and improving the interaction between the various parts of the structure. Bracing is used to reinforce existing or newly created openings and to consolidate sections of masonry characterised by discontinuities or insufficient connections. It is classified as a repair or local intervention if it affects individual parts and\/or elements of the structure and must not significantly alter its overall behaviour. In historic buildings, particular attention must be paid to the quality of the masonry, the design of the anchors and the minimisation of stress concentrations at the points of contact. The intervention must also ensure compatibility with the building\u2019s construction characteristics, minimising the impact on the historic fabric and prioritising solutions that can be inspected and, where possible, reversed.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Advantages<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The installation of tie-stays improves the local connections between structural elements and increases the load-bearing capacity of the affected sections of masonry, helping to reduce vulnerability in areas characterised by construction discontinuities. This measure is particularly effective for reinforcing existing or newly created openings and helps to limit the activation of local collapse mechanisms during seismic events. It is a well-established and extensively tested technique that can be effectively integrated with other seismic retrofitting measures as part of an overall strategy to reduce vulnerability.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Disadvantages and limitations of applicability<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The effectiveness of the ring beams depends on the quality of the existing masonry and on the correct design of the connections between the reinforcement structure and the masonry. Where the masonry is severely degraded or poorly bonded, the intervention may prove less effective and require preliminary consolidation work. Furthermore, inadequate design can lead to localised stress concentrations in the anchorage areas, whilst the presence of metal elements may have an architectural impact that must be assessed with particular care in buildings of historical interest.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Synergies, interactions and opportunities for complementary interventions<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The installation of tie-rods is frequently combined with other seismic retrofitting measures, such as the consolidation of masonry, the improvement of connections between walls and floor slabs, and the reinforcement of horizontal diaphragms, in order to enhance the building\u2019s overall response to seismic forces. In cases where the masonry shows signs of deterioration or reduced load-bearing capacity, it may be necessary to first consolidate the areas affected by the anchors or to locally restore the continuity of the masonry to ensure the full effectiveness of the intervention.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Assessment against the criteria<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Applicability and impact[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Efficacy<br \/>\nApplicability<br \/>\nEnvironmental sustainability<br \/>\nReversibility<br \/>\nImpact<br \/>\nDurability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">****<br \/>\n***<br \/>\n*****<br \/>\n**<br \/>\n***<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Cost and construction logistics[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Monetary cost<br \/>\nConstruction complexity<br \/>\nAvailability (time)<br \/>\nExecution time<br \/>\nMaintenance costs<br \/>\nRegionality<br \/>\nIntegrative interventions<br \/>\nUse restriction[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">****<br \/>\n***<br \/>\n****<br \/>\n***<br \/>\n*****<br \/>\n****<br \/>\n****<br \/>\n***<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Production process[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Degree of innovation<br \/>\nSustainability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Relationship with the indicators of the Risk Analysis Model<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]<em>Structural vulnerability<\/em>: Links between structural elements.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Riferimenti<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Borri, A., &amp; De Maria, A. (2018). Masonry strengthening with composite materials. In: Strengthening and Retrofitting of Existing Structures.<br \/>\nCattari, S., Lagomarsino, S., Bosiljkov, V., D&#8217;Ayala, D., et al. (2015). The guidelines for the seismic performance assessment of cultural heritage masonry structures by CEN TC346. Bulletin of Earthquake Engineering, 13, 927\u2013965.<br \/>\nConsiglio Superiore dei Lavori Pubblici (2019). Circolare 21 gennaio 2019, n. 7 C.S.LL.PP. \u2013 Istruzioni per l&#8217;applicazione dell&#8217;Aggiornamento delle &#8220;Norme Tecniche per le Costruzioni&#8221; D.M. 17 gennaio 2018.<br \/>\nDoglioni, F., Moretti, A., &amp; Petrini, V. (1994). Le chiese e il terremoto. LINT, Trieste.<br \/>\nICOMOS (2003). Principles for the Analysis, Conservation and Structural Restoration of Architectural Heritage.<br \/>\nLagomarsino, S., &amp; Cattari, S. (2015). PERPETUATE Guidelines for Seismic Performance-Based Assessment of Cultural Heritage Masonry Structures. Bulletin of Earthquake Engineering, 13, 13\u201347.<br \/>\nMinistero dei Beni e delle Attivit\u00e0 Culturali e del Turismo (2011). Linee guida per la valutazione e riduzione del rischio sismico del patrimonio culturale con riferimento alle Norme Tecniche per le Costruzioni di cui al D.M. 14 gennaio 2008.<br \/>\nMinistero delle Infrastrutture e dei Trasporti (2018). Aggiornamento delle Norme Tecniche per le Costruzioni. D.M. 17 gennaio 2018.<br \/>\nRoca, P., Cervera, M., Gariup, G., &amp; Pel\u00e0, L. (2010). Structural Analysis of Masonry Historical Constructions: Classical and Advanced Approaches. Archives of Computational Methods in Engineering, 17(3), 299\u2013325.<br \/>\nToma\u017eevi\u010d, M. (1999). Earthquake-Resistant Design of Masonry Buildings. Imperial College Press.[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text] &lt;- torna a home [\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16560&#8243; img_size=&#8221;800&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] MTTM&#8230;.<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16575","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16575","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/comments?post=16575"}],"version-history":[{"count":2,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16575\/revisions"}],"predecessor-version":[{"id":16578,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16575\/revisions\/16578"}],"wp:attachment":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/media?parent=16575"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}