{"id":16554,"date":"2026-09-28T12:30:50","date_gmt":"2026-09-28T10:30:50","guid":{"rendered":"https:\/\/www.corila.it\/?page_id=16554"},"modified":"2026-10-29T11:37:37","modified_gmt":"2026-10-29T10:37:37","slug":"mttm_sisma_1-1_inserimento_tiranti","status":"publish","type":"page","link":"https:\/\/www.corila.it\/en\/mttm_sisma_1-1_inserimento_tiranti\/","title":{"rendered":"MTTM_Sisma_1-1_Inserimento_tiranti"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: right;\"><a href=\"https:\/\/www.corila.it\/en\/metodologie-tecnologie-tecniche-e-materiali-per-ladeguamento-e-lefficientamento-di-edifici-e-siti-storici\/\">&lt;- back to home<\/a><\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16562&#8243; img_size=&#8221;800&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4>MTTM. Earthquake<\/h4>\n<h5>1. Intervention to reduce connection gaps<br \/>\n1.1 Inserting tie rods<\/h5>\n<p>MTTM-HEA-1.1[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Description<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The installation of tie rods is one of the most established methods for improving structural connections in masonry buildings, helping to limit the activation of local mechanisms and promote box-like behaviour of the structure during seismic events. The measure involves the installation of metal elements, usually made of steel, positioned between opposing walls or other structural elements, with the aim of absorbing tensile forces and improving the interaction between the various parts of the building. Tie rods are used primarily in historic buildings characterised by insufficient connections between orthogonal walls, between walls and floor slabs, or between other structural elements. When correctly designed and anchored, they help to counteract the opening of masonry, improve the transmission of horizontal forces and reduce the likelihood of local kinematic behaviour occurring during an earthquake. In buildings of historical interest, the design must pay particular attention to ensuring that the intervention is compatible with the existing structural characteristics, minimising the impact on the historic fabric and prioritising reversible or easily inspectable solutions. The design must also verify the effectiveness of the anchors, the quality of the affected masonry and the correct distribution of stresses, avoiding localised stress concentrations.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Advantages<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The installation of tie rods improves the connections between the various structural elements of the building, promoting a box-like behaviour of the structure during seismic events and helping to limit the activation of local collapse mechanisms. This is a widely tried and tested technique, generally minimally invasive, which, if correctly designed, can ensure a good level of compatibility with historic buildings. Furthermore, tie-rod systems can normally be inspected and, in many cases, can be removed without permanently altering the structure, thereby satisfying the principles of reversibility required for interventions on cultural heritage sites.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Disadvantages and limitations of applicability<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The effectiveness of the intervention depends to a large extent on the quality of the masonry and the correct design of the anchoring systems. Where the masonry is severely degraded, poorly bonded or characterised by reduced strength in the anchoring areas, the benefits may be limited, making preliminary consolidation work necessary. Furthermore, the presence of lintels or other exposed metal elements may have an architectural impact that is not always compatible with conservation requirements. Finally, it should be emphasised that the installation of tie rods does not resolve all the building\u2019s structural vulnerabilities and must therefore form part of an overall seismic retrofitting strategy.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Synergies, interactions and opportunities for complementary interventions<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The installation of tie rods is frequently combined with other seismic retrofitting measures, such as the consolidation of masonry, the strengthening of connections between walls and floor slabs, the reinforcement of horizontal diaphragms, and other techniques aimed at enhancing the building\u2019s box-like behaviour. Where masonry shows signs of deterioration or insufficient load-bearing capacity, it may be necessary to consolidate the anchorage areas beforehand in order to ensure the full effectiveness of the intervention.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Assessment against the criteria<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Applicability and impact[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Efficacy<br \/>\nApplicability<br \/>\nEnvironmental sustainability<br \/>\nReversibility<br \/>\nImpact<br \/>\nDurability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">****<br \/>\n****<br \/>\n*****<br \/>\n***<br \/>\n***<br \/>\n*****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Cost and construction logistics[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Monetary cost<br \/>\nConstruction complexity<br \/>\nAvailability (time)<br \/>\nExecution time<br \/>\nMaintenance costs<br \/>\nRegionality<br \/>\nIntegrative interventions<br \/>\nUse restriction[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n****<br \/>\n****<br \/>\n****<br \/>\n*****<br \/>\n****<br \/>\n***<br \/>\n***<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Production process[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Degree of innovation<br \/>\nSustainability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Relationship with the indicators of the Risk Analysis Model<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]<em>Structural vulnerability<\/em>: Links between structural elements.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>References<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Borri, A., &amp; De Maria, A. (2018). Masonry strengthening with composite materials. In: Strengthening and Retrofitting of Existing Structures.<br \/>\nCattari, S., Lagomarsino, S., Bosiljkov, V., D&#8217;Ayala, D., et al. (2015). The guidelines for the seismic performance assessment of cultural heritage masonry structures by CEN TC346. Bulletin of Earthquake Engineering, 13, 927\u2013965.<br \/>\nConsiglio Superiore dei Lavori Pubblici (2019). Circolare 21 gennaio 2019, n. 7 C.S.LL.PP. \u2013 Istruzioni per l&#8217;applicazione dell&#8217;Aggiornamento delle &#8220;Norme Tecniche per le Costruzioni&#8221; D.M. 17 gennaio 2018.<br \/>\nDoglioni, F., Moretti, A., &amp; Petrini, V. (1994). Le chiese e il terremoto. LINT, Trieste.<br \/>\nICOMOS (2003). Principles for the Analysis, Conservation and Structural Restoration of Architectural Heritage.<br \/>\nLagomarsino, S., &amp; Cattari, S. (2015). PERPETUATE Guidelines for Seismic Performance-Based Assessment of Cultural Heritage Masonry Structures. Bulletin of Earthquake Engineering, 13, 13\u201347.<br \/>\nMinistero dei Beni e delle Attivit\u00e0 Culturali e del Turismo (2011). Linee guida per la valutazione e riduzione del rischio sismico del patrimonio culturale con riferimento alle Norme Tecniche per le Costruzioni di cui al D.M. 14 gennaio 2008.<br \/>\nMinistero delle Infrastrutture e dei Trasporti (2018). Aggiornamento delle Norme Tecniche per le Costruzioni. D.M. 17 gennaio 2018.<br \/>\nRoca, P., Cervera, M., Gariup, G., &amp; Pel\u00e0, L. (2010). Structural Analysis of Masonry Historical Constructions: Classical and Advanced Approaches. Archives of Computational Methods in Engineering, 17(3), 299\u2013325.<br \/>\nToma\u017eevi\u010d, M. (1999). Earthquake-Resistant Design of Masonry Buildings. Imperial College Press.[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text] &lt;- back to home [\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16562&#8243; img_size=&#8221;800&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] MTTM&#8230;.<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16554","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16554","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/comments?post=16554"}],"version-history":[{"count":3,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16554\/revisions"}],"predecessor-version":[{"id":16806,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16554\/revisions\/16806"}],"wp:attachment":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/media?parent=16554"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}