{"id":16550,"date":"2026-09-25T13:32:01","date_gmt":"2026-09-25T11:32:01","guid":{"rendered":"https:\/\/www.corila.it\/?page_id=16550"},"modified":"2026-09-25T13:32:01","modified_gmt":"2026-09-25T11:32:01","slug":"mttm_mic2015_in_06_isolamento_interno","status":"publish","type":"page","link":"https:\/\/www.corila.it\/en\/mttm_mic2015_in_06_isolamento_interno\/","title":{"rendered":"MTTM_MIC2015_In_06_isolamento interno"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: right;\"><a href=\"https:\/\/www.corila.it\/en\/metodologie-tecnologie-tecniche-e-materiali-per-ladeguamento-e-lefficientamento-di-edifici-e-siti-storici\/\">&lt;- back to home<\/a><\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16143&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4>Urban Heat Islands and Energy Efficiency in Historic Buildings.<br \/>\nMIC 2015 Guidelines<\/h4>\n<h5>1. Internal and external insulation<br \/>\nIn.06. Internal insulation<\/h5>\n<p>MTTM-UHI_MIC-06[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Description<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Insulation on the internal walls of the building helps to improve the thermal performance of the building envelope, but does not guarantee the elimination of thermal bridges, which may lead to the formation of interstitial condensation, damp patches or mould. In particular, it helps to eliminate thermal bridges at vertical corners and at the junction between the window frame and the wall, whilst structural thermal bridges between vertical and horizontal elements require the insulation layer to be folded inwards by at least 100\u2013150 centimetres. As this work results in a reduction in the building\u2019s usable volume, it is good practice to choose high-performance insulation materials even at reduced thicknesses, such as M.1 heat-reflective insulation or M.2 vacuum insulation, which do not require a vapour barrier; in any case, where solid walls are present, it is advisable to use components with breathability and permeability properties similar to those of the masonry.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Advantages<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Internal insulation \u2013 which excludes the use of masonry as a thermal mass \u2013 is preferable in rooms where the heating system is used intermittently, as it reaches full capacity more quickly.<br \/>\nThis also reduces the usable internal volume and may create slopes or level differences on horizontal surfaces.<br \/>\nThe work is quick and easy to carry out and can be implemented selectively and in stages, although this approach increases the risk of condensation due to the significant discontinuity in the thermal properties of the building envelope.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Disadvantages and limitations of applicability<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Internal insulation involves altering the building\u2019s internal walls; it can therefore be installed provided it is compatible with the aesthetic and technical characteristics of the interior finishes.<br \/>\nDue to its lower efficiency compared with external insulation, this method is preferred when the external fa\u00e7ades cannot be altered or are unplastered, or when the building\u2019s form features a significant number of protruding elements such as balconies or loggias, the discontinuity of which is not resolved by external insulation in section 4.<br \/>\nCompared to external insulation, internal insulation presents greater discontinuities and, to reduce thermal bridges, requires a larger area to be clad: the vertical fa\u00e7ades, plus the extensions onto the ceilings and floors of each room.<br \/>\nInternal insulation limits heat absorption by thermal masses, increasing temperature fluctuations and preventing passive radiative cooling of the walls.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Synergies, interactions and opportunities for complementary interventions<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Given that internal insulation, when applied to horizontal surfaces, may require significant adaptation work (re-laying or extending flooring, relocating services), the work is more cost-effective when carried out in conjunction with general interior maintenance.<br \/>\nInternal insulation involves cladding all boundary surfaces, including horizontal partitions; furthermore, in the case of complex internal layouts, it can be supplemented by the use of thermal insulation plasters, in a manner similar to the external thermal insulation plasters In.5.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Assessment against the criteria<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Applicability and impact[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Efficacy<br \/>\nApplicability<br \/>\nEnvironmental sustainability<br \/>\nReversibility<br \/>\nImpact<br \/>\nQuality of redevelopment<br \/>\nDurability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n***<br \/>\n***<br \/>\n**<br \/>\n***<br \/>\n**<br \/>\n***<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Cost and construction logistics[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Monetary cost<br \/>\nConstruction complexity<br \/>\nAvailability (time)<br \/>\nExecution time<br \/>\nMaintenance costs<br \/>\nRegionality<br \/>\nIntegrative interventions<br \/>\nUse restriction[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n****<br \/>\n***<br \/>\n****<br \/>\n**<br \/>\n***<br \/>\n**<br \/>\n**<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Production process[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Degree of innovation<br \/>\nSustainability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Relationship with the indicators of the Risk Analysis Model<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]<em>Formal vulnerability<\/em>: Mitigations elements in the building &#8211; Roofs. Phisycal fa\u00e7ade elements for mitigation.<br \/>\n<em>Structural and building services vulnerabilities<\/em>: Building envelope and its efficiency.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Riferences<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]UNI EN ISO 13788:2003. Hygrometric performance of building components and elements. Italian National Standardisation Body. Milan.<br \/>\nUNI EN ISO 10211:2008. Thermal bridges in building construction. Italian National Standardisation Body. Milan.<br \/>\nMinisterial Decree of 26 January 2010. Amendment to the Decree of 11 March 2008 on the energy retrofitting of buildings[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text] &lt;- back to home [\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16143&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] Urban&#8230;<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16550","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16550","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/comments?post=16550"}],"version-history":[{"count":1,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16550\/revisions"}],"predecessor-version":[{"id":16555,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16550\/revisions\/16555"}],"wp:attachment":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/media?parent=16550"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}