{"id":16542,"date":"2026-09-25T12:27:51","date_gmt":"2026-09-25T10:27:51","guid":{"rendered":"https:\/\/www.corila.it\/?page_id=16542"},"modified":"2026-09-25T12:30:45","modified_gmt":"2026-09-25T10:30:45","slug":"mttm_mic2015_in_05_intonaco_termoisolante_esterno","status":"publish","type":"page","link":"https:\/\/www.corila.it\/en\/mttm_mic2015_in_05_intonaco_termoisolante_esterno\/","title":{"rendered":"MTTM_MIC2015_In_05_intonaco_termoisolante_esterno"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: right;\"><a href=\"https:\/\/www.corila.it\/en\/metodologie-tecnologie-tecniche-e-materiali-per-ladeguamento-e-lefficientamento-di-edifici-e-siti-storici\/\">&lt;- back to home<\/a><\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16141&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4>Urban Heat Islands and Energy Efficiency in Historic Buildings.<br \/>\nMIC 2015 Guidelines<\/h4>\n<h5>1. Internal and external insulation<br \/>\nIn.05. External thermal insulating plaster<\/h5>\n<p>MTTM-UHI_MIC-05[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Description<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Replacing external plaster with thermally insulating plaster ensures a significant reduction in thermal bridges, even where decorative features or protruding plastered elements are present. The material consists of a premixed mortar based on lightweight aggregates, hydraulic binders and special additive resins that improve the thermal properties of traditional plaster.<br \/>\nWhen refurbishing listed buildings, the use of natural lime or the addition of M.3 expanded or fibrous insulation to the mix ensures that the building envelope\u2019s breathability and permeability are similar to those of traditional masonry, without altering its hygroscopic behaviour.<br \/>\nThe insulating capacity of thermal insulation plaster is lower than that of external thermal insulation composite systems (ETICS), both due to the higher thermal conductivity of the materials used and the reduced thicknesses; for this reason, it is advisable, where possible, to apply successive layers of plaster until a thickness of 4 to 6 centimetres is achieved, which ensures adequate insulation of the building[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Advantages<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Thermal insulation plaster can be applied where external thermal insulation composite systems are not compatible with the aesthetic and technical characteristics of the fa\u00e7ades; furthermore, the plaster must cover the fa\u00e7ades evenly.<br \/>\nAs external thermal insulation plaster allows the masonry to act as a thermal mass, this solution is optimised for environments where the heating system operates continuously.<br \/>\nIt represents an optimisation of traditional materials, whose protective function makes them perishable and generally requires them to be replaced periodically: for this reason, the work can be incorporated into routine fa\u00e7ade maintenance activities.<br \/>\nThe application techniques do not require any changes to current systems, provided that a uniform and continuous thickness of the render is ensured.<br \/>\nThe use of natural lime and inorganic fibrous insulation materials as additives does not alter the hygrometric behaviour of the masonry, preventing the formation of interstitial condensation, damp patches or mould.<br \/>\nFinally, the ease of installation reduces the risk of thermal bridges resulting from poor workmanship during the insulation process.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Disadvantages and limitations of applicability<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Thermal insulation plaster has a lower insulating capacity than other systems.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Synergies, interactions and opportunities for complementary interventions<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Thermal insulation plaster offers an alternative to external thermal insulation composite systems (ETICS). To achieve better thermal insulation of the building, it should be combined with the replacement, upgrading or refurbishment of windows and doors (In,7-8) and the insulation of roofs (In,I -2-3 and the ground connection In.14-15, using either thermal insulation plaster or external wall insulation systems, provided that the insulating properties of the materials used do not differ too greatly, so as to avoid thermal bridges at the joints.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Assessment against the criteria<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Applicability and impact[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Efficacy<br \/>\nApplicability<br \/>\nEnvironmental sustainability<br \/>\nReversibility<br \/>\nImpact<br \/>\nQuality of redevelopment<br \/>\nDurability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n***<br \/>\n***<br \/>\n**<br \/>\n**<br \/>\n**<br \/>\n***<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Cost and construction logistics[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Monetary cost<br \/>\nConstruction complexity<br \/>\nAvailability (time)<br \/>\nExecution time<br \/>\nMaintenance costs<br \/>\nRegionality<br \/>\nIntegrative interventions<br \/>\nUse restriction[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n**<br \/>\n***<br \/>\n***<br \/>\n**<br \/>\n***<br \/>\n**<br \/>\n***<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Production process[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Degree of innovation<br \/>\nSustainability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Relationship with the indicators of the Risk Analysis Model<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]<em>Formal vulnerability<\/em>: Mitigations elements in the building &#8211; Roofs.<br \/>\n<em>Structural and building services vulnerabilities<\/em>: Building envelope and its efficiency.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Riferences<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]UNI EN ISO 13788:2003. Hygrometric performance of building components and elements. Italian National Standardisation Body. Milan.<br \/>\nUNI EN ISO 10211:2008. Thermal bridges in building construction. Italian National Standardisation Body. Milan.<br \/>\nMinisterial Decree of 26 January 2010. Amendment to the Decree of 11 March 2008 on the energy retrofitting of buildings[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text] &lt;- back to home [\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16141&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] Urban&#8230;<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16542","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16542","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/comments?post=16542"}],"version-history":[{"count":2,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16542\/revisions"}],"predecessor-version":[{"id":16547,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16542\/revisions\/16547"}],"wp:attachment":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/media?parent=16542"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}