{"id":16536,"date":"2026-09-25T10:29:34","date_gmt":"2026-09-25T08:29:34","guid":{"rendered":"https:\/\/www.corila.it\/?page_id=16536"},"modified":"2026-09-25T10:29:34","modified_gmt":"2026-09-25T08:29:34","slug":"mttm_mic2015_in_04_isolamento_esterno","status":"publish","type":"page","link":"https:\/\/www.corila.it\/en\/mttm_mic2015_in_04_isolamento_esterno\/","title":{"rendered":"MTTM_MIC2015_In_04_isolamento_esterno"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: right;\"><a href=\"https:\/\/www.corila.it\/en\/metodologie-tecnologie-tecniche-e-materiali-per-ladeguamento-e-lefficientamento-di-edifici-e-siti-storici\/\">&lt;- torna a home<\/a><\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16139&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4>Urban Heat Islands and Energy Efficiency in Historic Buildings.<br \/>\nMIC 2015 Guidelines<\/h4>\n<h5>1. Internal and external insulation<br \/>\nIn.04. External insulation<\/h5>\n<p>MTTM-UHI_MIC-04[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Description<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The external insulation of the building, applied uniformly and without interruption across the entire surface (external thermal insulation system), creates a continuous barrier against heat transfer and controls the build-up of moisture within the wall. It consists of applying insulation panels to the entire external surface of the building, which are then protected by a protective finishing layer made from specialised plasters.<br \/>\nWhen refurbishing historic buildings, to ensure the reversibility of the work, it is good practice to avoid gluing the panels in place, opting instead for the use of approved wall plugs or profiles, depending on the coplanarity of the wall substrate. The choice of insulation must be compatible with the permeability and breathability of the wall system: in the case of solid-wall buildings, the use of natural organic fibrous materials (M.4) with good hygroscopic properties is recommended.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Advantages<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]As external insulation allows the masonry to act as a thermal mass, this solution is optimised for environments where the heating system operates continuously.<br \/>\nThe main advantages lie in the ability to clad the external surface uniformly, ensuring effective control of thermal bridges in buildings without protruding structural elements, and minimising heat loss and the build-up of surface condensation, damp patches or mould inside the rooms.<br \/>\nFurthermore, as the external insulation increases the wall\u2019s thickness towards the outside, it does not take up space from the internal rooms, as is the case with the In.6 internal lining insulation.<br \/>\nFinally, the use of external insulation allows the thermal inertia of the walls on the inside of the building to be utilised to stabilise comfort conditions and increase radiant heating, thereby optimising the operation of the air-conditioning system. The thermal mass can then be used, during the summer, to absorb and dissipate excess heat, improving the building\u2019s passive cooling.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Disadvantages and limitations of applicability<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]External insulation involves altering the building\u2019s external elevations; it may therefore only be carried out if it is compatible with the aesthetic and technical characteristics of the fa\u00e7ade.<br \/>\nThe work may not be cost-effective if the building\u2019s form features a significant number of geometric discontinuities that cannot be interrupted or covered by the insulating layer (for example, where there are balconies or loggias).<br \/>\nThe main disadvantage of external insulation is the alteration of the external elevations; furthermore, it has a significant impact on the building\u2019s hygrometric behaviour.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Synergies, interactions and opportunities for complementary interventions<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]External insulation of vertical openings is most effective at reducing thermal bridges when combined with insulation of the roof (In.I -2-3) and the ground connection (In.14-15), and with the replacement, upgrading or refurbishment of window and door frames (In.7-8); however, to prevent condensation, it is advisable to ensure a certain degree of ventilation within the system.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Assessment against the criteria<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Applicability and impact[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Efficacy<br \/>\nApplicability<br \/>\nEnvironmental sustainability<br \/>\nReversibility<br \/>\nImpact<br \/>\nQuality of redevelopment<br \/>\nDurability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">*****<br \/>\n**<br \/>\n***<br \/>\n*<br \/>\n*<br \/>\n**<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Cost and construction logistics[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Monetary cost<br \/>\nConstruction complexity<br \/>\nAvailability (time)<br \/>\nExecution time<br \/>\nMaintenance costs<br \/>\nRegionality<br \/>\nIntegrative interventions<br \/>\nUse restriction[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">**<br \/>\n**<br \/>\n***<br \/>\n**<br \/>\n***<br \/>\n***<br \/>\n**<br \/>\n***<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Production process[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Degree of innovation<br \/>\nSustainability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">**<br \/>\n***<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Relationship with the indicators of the Risk Analysis Model<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]<em>Formal vulnerability<\/em>: Mitigations elements in the building &#8211; Roofs. Building albedo \u2013 Facades.<br \/>\n<em>Structural and building services vulnerabilities<\/em>: Building envelope and its efficiency.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Riferences<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]UNI EN ISO 13788:2003. Hygrometric performance of building components and elements. Italian National Standardisation Body. Milan.<br \/>\nUNI EN ISO 10211:2008. Thermal bridges in building construction. Italian National Standardisation Body. Milan.<br \/>\nMinisterial Decree of 26 January 2010. Amendment to the Decree of 11 March 2008 on the energy retrofitting of buildings[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text] &lt;- torna a home [\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16139&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] Urban&#8230;<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16536","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16536","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/comments?post=16536"}],"version-history":[{"count":2,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16536\/revisions"}],"predecessor-version":[{"id":16539,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16536\/revisions\/16539"}],"wp:attachment":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/media?parent=16536"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}