{"id":16385,"date":"2026-07-08T16:23:54","date_gmt":"2026-07-08T14:23:54","guid":{"rendered":"https:\/\/www.corila.it\/?page_id=16385"},"modified":"2026-07-08T16:23:54","modified_gmt":"2026-07-08T14:23:54","slug":"mttm_mic2015_in_03_isolamento_intradosso","status":"publish","type":"page","link":"https:\/\/www.corila.it\/en\/mttm_mic2015_in_03_isolamento_intradosso\/","title":{"rendered":"MTTM_MIC2015_In_03_isolamento_intradosso"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: right;\"><a href=\"https:\/\/www.corila.it\/en\/metodologie-tecnologie-tecniche-e-materiali-per-ladeguamento-e-lefficientamento-di-edifici-e-siti-storici\/\">&lt;- torna a home<\/a><\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16209&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4>MTTM. Urban Heat Islands and Energy Efficiency in Historic Buildings. MIC 2015 Guidelines<\/h4>\n<h5>1. Internal and external insulation<br \/>\nIn.03. Insulation of the roof intrados.<\/h5>\n<p>MTTM-UHI_MIC-03[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Description<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Insulation on the underside of the roof improves the insulation of the building envelope when it is not possible to work on the extrados. Furthermore, it is good practice to choose high-performance insulation materials even with thin layers, such as M.I. heat-reflecting or M.2 vacuum insulation. Installation can involve the use of self-supporting panels, fixed to the underside of the attic or the load-bearing structure of the sloping roof using dry anchors. If the existing volumes allow it, the insulation can be spaced away from the attic, creating an internal ventilated cavity that reduces condensation, improves summer cooling, and accommodates the installation of systems. For insulation with panels inserted directly into the existing attic, it is advisable to choose materials with low thermal conductivity and good vapor permeability. In insulated and ventilated false ceilings, it is also possible to use hygroscopic materials, as the air cavity prevents the formation of interstitial and superficial condensation.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Advantages<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Due to its lower efficiency compared to external insulation, this method is preferred when the external roofing cannot be altered.<br \/>\nThis method allows for the creation of a false ceiling to house the systems, which can be very cost-effective when combined with the overall system.<br \/>\nInsulation on the underside is quick and easy to install and can be applied selectively and staggered, although this method increases the risk of condensation as it significantly disrupts the thermal properties of the envelope.<br \/>\nIn the case of pitched or skeleton roofs, the system protects the structure from thermal shock, helping to increase its lifespan.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Disadvantages and limitations of applicability<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Since the intervention reduces the usable volume of the rooms, it is necessary to ensure compliance with the height restrictions set by regulations.<br \/>\nInsulation on the underside of the roof alters the appearance of the attic; it can only be implemented if it is compatible with the aesthetic and technological characteristics of the rooms below the roof, or when the attic must not be left exposed.<br \/>\nSince internal insulation excludes the use of the roof&#8217;s load-bearing structure as thermal mass, it is preferable for rooms with intermittent use of the heating system or for non-habitable spaces.<br \/>\nCompared to insulation on the underside, insulation on the underside presents greater discontinuity and limits the use of the roof&#8217;s load-bearing structures as thermal mass.<br \/>\nIt cannot eliminate structural thermal bridges, which can lead to interstitial condensation, damp stains, or mold.<br \/>\nIt reduces the usable internal volume, especially if a cavity is created.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Synergies, interactions and opportunities for complementary interventions<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Internal insulation requires lining all boundary surfaces, including vertical In.6 closures; furthermore, in the case of complex internal morphologies, it can be integrated with the use of thermal insulating plasters, in a manner similar to the external vertical In.5 thermal insulating plasters.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Assessment against the criteria<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Applicability and impact[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Efficacy<br \/>\nApplicability<br \/>\nEnvironmental sustainability<br \/>\nReversibility<br \/>\nImpact<br \/>\nQuality of redevelopment<br \/>\nDurability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n***<br \/>\n***<br \/>\n***<br \/>\n****<br \/>\n**<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Cost and construction logistics[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Monetary cost<br \/>\nConstruction complexity<br \/>\nAvailability (time)<br \/>\nExecution time<br \/>\nMaintenance costs<br \/>\nRegionality<br \/>\nIntegrative interventions<br \/>\nUse restriction[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n****<br \/>\n***<br \/>\n***<br \/>\n***<br \/>\n***<br \/>\n***<br \/>\n***<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Production process[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Degree of innovation<br \/>\nSustainability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Relationship with the indicators of the Risk Analysis Model<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]<em>Formal vulnerability<\/em>: Mitigations elements in the building &#8211; Roofs.<br \/>\n<em>Structural and building services vulnerabilities<\/em>: Building envelope and its efficiency; Roof constructions materials and their thermal resilience.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>References<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]UNI EN ISO 13788:2003. Hygrometric performance of building components and elements. Italian National Standardisation Body. Milan.<br \/>\nUNI EN ISO 10211:2008. Thermal bridges in building construction. Italian National Standardisation Body. Milan.<br \/>\nMinisterial Decree of 26 January 2010 (Italy). Amendment to the Decree of 11 March 2008 on the energy retrofitting of buildings.[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text] &lt;- torna a home [\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16209&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] MTTM&#8230;.<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16385","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16385","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/comments?post=16385"}],"version-history":[{"count":2,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16385\/revisions"}],"predecessor-version":[{"id":16388,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16385\/revisions\/16388"}],"wp:attachment":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/media?parent=16385"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}