{"id":16374,"date":"2026-07-08T14:56:45","date_gmt":"2026-07-08T12:56:45","guid":{"rendered":"https:\/\/www.corila.it\/?page_id=16374"},"modified":"2026-07-08T14:57:52","modified_gmt":"2026-07-08T12:57:52","slug":"mttm_mic2015_in_02_isolamento_estradosso_ventilato","status":"publish","type":"page","link":"https:\/\/www.corila.it\/en\/mttm_mic2015_in_02_isolamento_estradosso_ventilato\/","title":{"rendered":"MTTM_MIC2015_In_02_isolamento_estradosso_ventilato"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: right;\"><a href=\"https:\/\/www.corila.it\/en\/metodologie-tecnologie-tecniche-e-materiali-per-ladeguamento-e-lefficientamento-di-edifici-e-siti-storici\/\">&lt;- back to home<\/a><\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16135&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4>Urban Heat Islands and Energy Efficiency in Historic Buildings. MIC Guidelines 2015<\/h4>\n<h5>1. Internal and external insulation<br \/>\nIn.02. Ventilated roof extrados insulation.<\/h5>\n<p>MTTM-UHI_MIC-02[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Description<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Ventilated roof insulation improves the insulation of the building envelope and reduces thermal bridges due to its shape and structure. This procedure involves removing and replacing the roof covering, applying a continuous layer of insulating panels and creating a ventilated cavity behind the insulation. It can also be installed on flat roofs but is typically used on pitched roofs with a wooden structure. The ventilated layer prevents condensation and, during the summer, facilitates convective motion that dissipates heat from the structures, contributing to passive cooling of the attic spaces.<br \/>\nTo ensure the system&#8217;s reversibility, it is good practice to use dry joints for the insulating panels; furthermore, it is necessary to ensure that the load-bearing structure is compatible with the overload resulting from the installation of the panels and the cavity support. The ventilated layer generally eliminates the need for a vapor barrier; Since the cavity prevents water stagnation, it is possible to use both waterproof insulation and hygroscopic and fibrous materials.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Advantages<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]For pitched roofs, if the existing tiles are in good condition or have historical or aesthetic value that requires preservation, they can be reinstated on the new roof.<br \/>\nSince external insulation allows the roof&#8217;s load-bearing structure to be used as thermal mass, the solution is optimized for attic spaces with continuous heating operation. If the insulation layer is on the extrados, similar to the external insulation of In.4 vertical closures, it eliminates structural thermal bridges, increasing the surface temperature of the internal walls, while the presence of a ventilated cavity reduces the risk of condensation.<br \/>\nThe use of external insulation allows the thermal inertia of the roof&#8217;s load-bearing structure to be exploited to stabilize internal comfort conditions and optimize the operation of the air conditioning system.<br \/>\nFor pitched or skeleton roofs, the system protects the structure from thermal shock, helping to increase its lifespan.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Disadvantages and limitations of applicability<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The major disadvantage of ventilated roof insulation is the need to completely renovate the roof and modify the height of the eaves to accommodate the ventilated cavity.<br \/>\nVentilated roof insulation alters the building&#8217;s elevations and the eaves&#8217; heights: it can therefore only be implemented if it is compatible with the aesthetic and technological characteristics of the roof.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Synergies, interactions and opportunities for complementary interventions<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]External insulation of an unventilated roof is most effective at reducing thermal bridges when combined with external insulation of the corresponding vertical envelope elements (In.4) and the replacement, retrofitting or refurbishment of windows and doors (In.7\u00b78); to prevent condensation, it is advisable to ensure a certain degree of ventilation within the system.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Assessment against the criteria<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Applicability and impact[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Efficacy<br \/>\nApplicability<br \/>\nEnvironmental sustainability<br \/>\nReversibility<br \/>\nImpact<br \/>\nQuality of redevelopment<br \/>\nDurability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">****<br \/>\n***<br \/>\n***<br \/>\n**<br \/>\n**<br \/>\n**<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Cost and construction logistics[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Monetary cost<br \/>\nConstruction complexity<br \/>\nAvailability (time)<br \/>\nExecution time<br \/>\nMaintenance costs<br \/>\nRegionality<br \/>\nIntegrative interventions<br \/>\nUse restriction[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">**<br \/>\n**<br \/>\n***<br \/>\n**<br \/>\n****<br \/>\n***<br \/>\n***<br \/>\n***<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Production process[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Degree of innovation<br \/>\nSustainability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n***<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Relationship with the indicators of the Risk Analysis Model<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]<em>Formal vulnerability<\/em>: Building albedo &#8211; Roofs; Mitigations elements in the building &#8211; Roofs.<br \/>\n<em>Structural and building services vulnerabilities<\/em>: Building envelope and its efficiency; Roof constructions materials and their thermal resilience.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>References<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]UNI EN ISO 13788:2003. Hygrometric performance of building components and elements. Italian National Standardisation Body. Milan.<br \/>\nUNI EN ISO 10211:2008. Thermal bridges in building construction. Italian National Standardisation Body. Milan.<br \/>\nMinisterial Decree of 26 January 2010 (Italy). Amendment to the Decree of 11 March 2008 on the energy retrofitting of buildings.[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text] &lt;- back to home [\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16135&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] Urban&#8230;<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16374","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16374","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/comments?post=16374"}],"version-history":[{"count":3,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16374\/revisions"}],"predecessor-version":[{"id":16379,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16374\/revisions\/16379"}],"wp:attachment":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/media?parent=16374"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}