{"id":16320,"date":"2026-06-25T13:34:22","date_gmt":"2026-06-25T11:34:22","guid":{"rendered":"https:\/\/www.corila.it\/?page_id=16320"},"modified":"2026-06-25T13:34:22","modified_gmt":"2026-06-25T11:34:22","slug":"mttm_mic2015_in_19_applicazione_pellicole","status":"publish","type":"page","link":"https:\/\/www.corila.it\/en\/mttm_mic2015_in_19_applicazione_pellicole\/","title":{"rendered":"MTTM_MIC2015_In_19_Applicazione_pellicole"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: right;\"><a href=\"https:\/\/www.corila.it\/en\/metodologie-tecnologie-tecniche-e-materiali-per-ladeguamento-e-lefficientamento-di-edifici-e-siti-storici\/\">&lt;- back to home<\/a><\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16189&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4>MTTM. Urban Heat Islands and Energy Efficiency in Historic Buildings. MIC 2015 Guidelines<\/h4>\n<h5>4. Application of films and screens<br \/>\nIn.19. Application of solar control films to glass<\/h5>\n<h5>MTTM-UHI_MIC-19<\/h5>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Description<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The measure involves the installation of solar control films to reduce heat gain through the transparent building envelope. The light transmission of the glass and the film must be such as to ensure the user\u2019s visual comfort, whilst maintaining a daylight factor (FLD) of more than 2 per cent. There are two types of film: reflective film, which is silver in colour and has a slight mirror-like finish, to be applied to the outer pane; and semi-reflective film with a slight tint, to be applied to the inner pane as it is less resistant to weathering and environmental acidity.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Advantages<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The fitting of a special film is a type of operation which, more than any other, allows the original aesthetic characteristics of the window or door to remain unchanged, as the film is transparent.<br \/>\nAs it blocks almost all ultraviolet radiation, it is particularly suitable for buildings housing objects of high artistic value.<br \/>\nThe installation of a solar control film significantly reduces the light transmission of the glass (50\u201360%): although it provides almost total protection against ultraviolet radiation and fairly effective blocking of the infrared spectrum, it allows almost the entire visible spectrum to pass through.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Disadvantages and limitations of applicability<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]In any case, an assessment of the condition of the existing window is required to determine the technical feasibility and cost-effectiveness of the work. It is important to assess the film\u2019s colour rendering properties in accordance with the building\u2019s function.<br \/>\nFilms have varying levels of mechanical and chemical resistance and durability depending on the type of surface coating: their suitability must be assessed on a case-by-case basis.<br \/>\nThe film must be fitted by specialist technical staff: incorrect application could lead to problems with the adhesion and uniformity of the adhesive, the chemical and physical compatibility between the film and the adhesive, and the durability of the film. Maintenance must be carried out using techniques and products compatible with the chemical, physical and mechanical resistance of the material.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Synergies, interactions and opportunities for complementary interventions<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The cost-effectiveness of the work increases with the use of double glazing made of float glass, frames with good thermal insulation performance, and the absence of air infiltration at the joints between the glazing and the frame, between the fixed and movable sashes, and between the window and the wall cavity.<br \/>\nIt may be necessary to combine this with insulation work and sealing of air infiltration at the frame. In. 11.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Assessment against the criteria<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Applicability and impact[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Efficacy<br \/>\nApplicability<br \/>\nEnvironmental sustainability<br \/>\nReversibility<br \/>\nImpact<br \/>\nQuality of redevelopment<br \/>\nDurability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">****<br \/>\n****<br \/>\n***<br \/>\n****<br \/>\n****<br \/>\n**<br \/>\n***<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Cost and construction logistics[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Monetary cost<br \/>\nConstruction complexity<br \/>\nAvailability (time)<br \/>\nExecution time<br \/>\nMaintenance costs<br \/>\nRegionality<br \/>\nIntegrative interventions<br \/>\nUse restriction[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n**<br \/>\n***<br \/>\n****<br \/>\n***<br \/>\n***<br \/>\n***<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Production process[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Degree of innovation<br \/>\nSustainability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">*****<br \/>\n*****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Relationship with the indicators of the Risk Analysis Model<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]<em>Formal vulnerability<\/em>: Mitigations elements in the building \u2013 Roofs; Mitigations elements in the building &#8211; Facades.<br \/>\n<em>Structural and building services vulnerabilities<\/em>: Building envelope and its efficiency[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>References<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]UNI EN 15251:2008. Criteria for the design of the indoor environment and for the assessment of the energy performance of buildings, with regard to indoor air quality, thermal environment, lighting and acoustics<br \/>\nUNI 10339 (Italy). Air-handling systems for comfort purposes.[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text] &lt;- back to home [\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16189&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] MTTM&#8230;.<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16320","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16320","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/comments?post=16320"}],"version-history":[{"count":2,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16320\/revisions"}],"predecessor-version":[{"id":16326,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16320\/revisions\/16326"}],"wp:attachment":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/media?parent=16320"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}