{"id":16294,"date":"2026-06-23T17:05:15","date_gmt":"2026-06-23T15:05:15","guid":{"rendered":"https:\/\/www.corila.it\/?page_id=16294"},"modified":"2026-06-25T12:13:26","modified_gmt":"2026-06-25T10:13:26","slug":"mttm_mic2015_in_11_seconda_anta_vetrata","status":"publish","type":"page","link":"https:\/\/www.corila.it\/en\/mttm_mic2015_in_11_seconda_anta_vetrata\/","title":{"rendered":"MTTM_MIC2015_In_11_seconda_anta_vetrata"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: right;\"><a href=\"https:\/\/www.corila.it\/en\/metodologie-tecnologie-tecniche-e-materiali-per-ladeguamento-e-lefficientamento-di-edifici-e-siti-storici\/\">&lt;- back to home<\/a><\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16153&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4>MTTM. Urban Heat Islands and Energy Efficiency in Historic Buildings. MIC 2015 Guidelines<\/h4>\n<h5>4. Application of films and screens<br \/>\nIn.11. Frame insulation and air tightness<\/h5>\n<p>MTTM-UHI_MIC-11[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Description<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]This measure involves sealing the joint between the window opening and the frame and installing airtight gaskets to reduce air leakage from the building. Leaks occur primarily in the areas where the sash closes against the frame. To optimize performance, the window must resist wind gusts while simultaneously allowing air to pass through when subjected to atmospheric pressure or when a temperature difference arises between the interior and exterior of the building envelope.<br \/>\nSealants are technical components that enhance the window\u2019s waterproofing, airtightness, and weather resistance. Gaskets are high-performance polymer-based components that help improve water resistance and thermal and acoustic insulation, while reducing the force required to close the sashes.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Advantages<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Improving the airtightness of the window frame by sealing it or installing gaskets is the type of work that, more than any other, allows the window\u2019s original aesthetic characteristics to remain unchanged.<br \/>\nIn any case, an assessment of the existing window\u2019s condition is necessary to determine the technical feasibility and economic viability of the project.<br \/>\nNatural air infiltration can be reduced by up to 90%, improving thermal comfort and indoor air quality.<br \/>\nThis is a simple and inexpensive measure to implement in existing buildings. It is necessary to periodically check the condition of the windows and monitor air infiltration by establishing a maintenance plan.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Disadvantages and limitations of applicability<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]In existing windows and doors, initial performance declines over time, especially when there are issues such as deterioration, malfunction, or repeated opening of the unit.<br \/>\nRenovation is cost-effective for glazing with good thermal insulation and frames that are in good condition and function properly.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Synergies, interactions and opportunities for complementary interventions<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]This measure is cost-effective when combined with the replacement of In.8 glazing or the installation of In.12 low-emissivity films. For sealants, the choice of material depends on the type of joint to be created, the application substrate, and the system\u2019s stresses; it is necessary to verify the physical compatibility between the construction materials and the sealants. Seals can be made of elastomeric or plastomeric materials. Even better thermal insulation results are achieved with self-inflating perimeter seals, which improve airtightness. Air tightness must be checked periodically as part of a maintenance program, verifying: the integrity of the existing glazing; the proper closure, coplanarity, and sealing of the joint between the fixed and movable frames; the proper closing of sashes and panels; the condition of existing sealants and gaskets; and the proper functioning of latches and closing mechanisms.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Assessment against the criteria<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Applicability and impact[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Efficacy<br \/>\nApplicability<br \/>\nEnvironmental sustainability<br \/>\nReversibility<br \/>\nImpact<br \/>\nQuality of redevelopment<br \/>\nDurability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">****<br \/>\n*****<br \/>\n***<br \/>\n*****<br \/>\n*****<br \/>\n**<br \/>\n***<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Cost and construction logistics[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Monetary cost<br \/>\nConstruction complexity<br \/>\nAvailability (time)<br \/>\nExecution time<br \/>\nMaintenance costs<br \/>\nRegionality<br \/>\nIntegrative interventions<br \/>\nUse restriction[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">*****<br \/>\n*****<br \/>\n****<br \/>\n*****<br \/>\n**<br \/>\n***<br \/>\n**<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Production process[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Degree of innovation<br \/>\nSustainability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Relationship with the indicators of the Risk Analysis Model<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]<em>Formal vulnerability<\/em>: Mitigations elements in the building \u2013 Roofs; Mitigations elements in the building &#8211; Facades.<br \/>\n<em>Structural and building services vulnerabilities<\/em>: Building envelope and its efficiency[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>References<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Legislative Decree No. 311 of 2006 (Italy). Limit values for the thermal transmittance \u2018U\u2019 of \u2018transparent enclosures including frames\u2019 (complete window and door units) and glazing.<br \/>\nUNI EN 14351-1; 2010. Windows and doors \u2013 Product standard, performance characteristics.<br \/>\nUNI EN ISO 10077. Thermal performance of windows, doors and shading devices \u2013 Calculation of thermal transmittance.[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text] &lt;- back to home [\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16153&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] MTTM&#8230;.<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16294","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16294","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/comments?post=16294"}],"version-history":[{"count":2,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16294\/revisions"}],"predecessor-version":[{"id":16305,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16294\/revisions\/16305"}],"wp:attachment":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/media?parent=16294"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}