{"id":16279,"date":"2026-06-23T14:24:55","date_gmt":"2026-06-23T12:24:55","guid":{"rendered":"https:\/\/www.corila.it\/?page_id=16279"},"modified":"2026-06-25T12:06:07","modified_gmt":"2026-06-25T10:06:07","slug":"mttm_mic2015_in_07_sostituzione_serramenti_alta_prestazione","status":"publish","type":"page","link":"https:\/\/www.corila.it\/en\/mttm_mic2015_in_07_sostituzione_serramenti_alta_prestazione\/","title":{"rendered":"MTTM_MIC2015_In_07_sostituzione_serramenti_alta_prestazione"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: right;\"><a href=\"https:\/\/www.corila.it\/en\/metodologie-tecnologie-tecniche-e-materiali-per-ladeguamento-e-lefficientamento-di-edifici-e-siti-storici\/\">&lt;- back to home<\/a><\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16145&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4>MTTM. Urban Heat Islands and Energy Efficiency in Historic Buildings. MIC 2015 Guidelines.<\/h4>\n<h5>2. Replacement of windows and installation of glass<br \/>\nIn.07. Replacement of windows with high energy performance models.<\/h5>\n<p>MTTM-UHI_MIC-07[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Description<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]In the energy balance of a building envelope, windows and doors represent a critical factor due to their structural and functional characteristics, as they must balance the needs for thermal insulation, solar control, visual access, microclimatic and acoustic comfort, and user safety. This measure involves replacing existing windows with high-energy-performance windows. To optimize energy efficiency, it is necessary to design a glazing system that balances thermal insulation and solar control performance, and then select the frame characteristics based on aesthetic requirements, cost, technical performance, and airtightness.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Advantages<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Replacing a window results in:<\/p>\n<ul>\n<li>a reduction in the thermal load associated with windows and doors of between 40% and 1&#8217;80%, depending on the type of glass being replaced;<\/li>\n<li>a reduction in solar heat gain through windows of up to 70% when using low-emissivity or selective glass;<\/li>\n<li>a reduction in air infiltration of up to 94% with a high-seal window.<\/li>\n<\/ul>\n<p>Proper installation of a new window ensures airtightness, preventing unwanted air infiltration.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Disadvantages and limitations of applicability<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]A complete window replacement first requires an assessment of the intrinsic value of the existing window frame. If the window frame can be considered a valuable feature that contributes to the building\u2019s value, less drastic measures will be necessary.<br \/>\nHowever, care must be taken to ensure that the airtightness of the new components does not compromise room ventilation, which must be guaranteed\u2014if necessary, through controlled mechanical or manual ventilation.<br \/>\nA lack of air exchange could lead to the formation of surface condensation, causing thermal discomfort and deterioration of the walls.<br \/>\nThe benefits of replacing the window are strongly influenced by the type of frame (fixed\/movable; thermal break; airtightness) and the type of glass (selective glass, energy-efficient glass, double-pane glass, etc.).[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Synergies, interactions and opportunities for complementary interventions<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Choosing the type of window to install requires a careful assessment of the performance of the existing window, local climatic conditions, the window\u2019s location, the building\u2019s function, and installation techniques. It is necessary to consider the window\u2019s dimensional and material compatibility with the wall opening and the stratigraphy of the exterior wall. The window should be installed in continuity with the thermal insulation and the wall cavity, if present; the window box and the radiator recess beneath the window, if present, should be insulated. It is also advisable to evaluate the thermal performance of the existing masonry to ensure that the behavior of the new window complements\u2014rather than conflicts with\u2014that of the other parts of the building.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Assessment against the criteria<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Applicability and impact[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Efficacy<br \/>\nApplicability<br \/>\nEnvironmental sustainability<br \/>\nReversibility<br \/>\nImpact<br \/>\nQuality of redevelopment<br \/>\nDurability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">****<br \/>\n***<br \/>\n***<br \/>\n***<br \/>\n***<br \/>\n**<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Cost and construction logistics[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Monetary cost<br \/>\nConstruction complexity<br \/>\nAvailability (time)<br \/>\nExecution time<br \/>\nMaintenance costs<br \/>\nRegionality<br \/>\nIntegrative interventions<br \/>\nUse restriction[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n***<br \/>\n***<br \/>\n***<br \/>\n****<br \/>\n***<br \/>\n***<br \/>\n***<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Production process[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Degree of innovation<br \/>\nSustainability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">****<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Relationship with the indicators of the Risk Analysis Model<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]<em>Formal vulnerability<\/em>: Mitigations elements in the building \u2013 Roofs; Mitigations elements in the building &#8211; Facades.<br \/>\n<em>Structural and building services vulnerabilities<\/em>: Building envelope and its efficiency[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>References<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Legislative Decree No. 311 of 2006 (Italy). Limit values for the thermal transmittance \u2018U\u2019 of \u2018transparent enclosures including frames\u2019 (complete window and door units) and glazing.<br \/>\nUNI EN 14351-1; 2010. Windows and doors \u2013 Product standard, performance characteristics.<br \/>\nUNI EN ISO 10077. Thermal performance of windows, doors and shading devices \u2013 Calculation of thermal transmittance.[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text] &lt;- back to home [\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16145&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] MTTM&#8230;.<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16279","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16279","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/comments?post=16279"}],"version-history":[{"count":5,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16279\/revisions"}],"predecessor-version":[{"id":16301,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16279\/revisions\/16301"}],"wp:attachment":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/media?parent=16279"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}