{"id":16077,"date":"2026-06-19T15:16:51","date_gmt":"2026-06-19T13:16:51","guid":{"rendered":"https:\/\/www.corila.it\/?page_id=16077"},"modified":"2026-06-25T12:08:08","modified_gmt":"2026-06-25T10:08:08","slug":"mttm_mic2015_in_01_isolamento_estradosso_non_ventilato","status":"publish","type":"page","link":"https:\/\/www.corila.it\/en\/mttm_mic2015_in_01_isolamento_estradosso_non_ventilato\/","title":{"rendered":"MTTM_MIC2015_In_01_isolamento_estradosso_non_ventilato"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: right;\"><a href=\"https:\/\/www.corila.it\/en\/metodologie-tecnologie-tecniche-e-materiali-per-ladeguamento-e-lefficientamento-di-edifici-e-siti-storici\/\">&lt;- back to home<\/a><\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16133&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4>MTTM. Urban Heat Islands and Energy Efficiency in Historic Buildings. MIC 2015 Guidelines<\/h4>\n<h5>1. Internal and external insulation<br \/>\nIn.01. Non-ventilated roof extrados insulation.<\/h5>\n<p>MTTM-UHI_MIC-01[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Description<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Insulating the upper surface of an unventilated roof improves the thermal performance of the building envelope and reduces structural and geometric thermal bridges. The work involves removing and replacing the roof covering by applying a continuous layer of insulation panels protected on the outside by a finishing layer, which may consist of tiles in the case of pitched roofs, or gravel or paving in the case of flat roofs. To ensure the reversibility of the system, it is good practice to use dry joints for the insulation panels; furthermore, it is necessary to verify that the supporting structure is compatible with the additional load resulting from the installation of the panels. Depending on the specific characteristics of the roof, it is possible to opt for the \u2018warm roof\u2019 or \u2018inverted roof\u2019 system; the use of a vapour barrier can be avoided by using waterproof insulation or by combining hygroscopic and breathable insulation (such as M.4 fibrous materials) with a 1.5\u20132% slope beneath the insulation layer to allow water to drain away. During installation, it is necessary to check the continuity of the insulation layer to prevent leaks; the most critical points concern thermal bridges due to shape, rainwater collection points and slopes.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Advantages<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]If the insulation layer is on the outer surface, as with the external insulation system for In.5 vertical enclosures, it ensures the elimination of structural thermal bridges, increasing the surface temperature of the internal walls and reducing the risk of condensation. The use of external insulation allows the thermal inertia of the roof\u2019s load-bearing structure to be utilised to stabilise indoor comfort conditions and optimise the operation of the air-conditioning system.<br \/>\nIn the case of pitched roofs or those with a timber frame, the system protects the structure from thermal shocks, helping to extend its lifespan.<br \/>\nIn the case of pitched roofs, if the existing tiles are in good condition or have historical and aesthetic value that requires their preservation, they can be reinstalled on the new roof.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Disadvantages and limitations of applicability<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]Insulation on the upper surface of an unventilated roof alters the building\u2019s external appearance; it may therefore only be installed if it is compatible with the aesthetic and technical characteristics of the roof.<br \/>\nThe main disadvantage of insulation on the upper surface of an unventilated roof is the need for a complete roof refurbishment, which may alter the external appearance.<br \/>\nAs external insulation allows the roof\u2019s load-bearing structure to act as a thermal mass, this solution is optimised for occupied attic spaces where the heating system operates continuously.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Synergies, interactions and opportunities for complementary interventions<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]External insulation of an unventilated roof is most effective at reducing thermal bridges when combined with external insulation of the corresponding vertical envelope elements (In.4) and the replacement, retrofitting or refurbishment of windows and doors (In.7\u00b78); to prevent condensation, it is advisable to ensure a certain degree of ventilation within the system.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Assessment against the criteria<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Applicability and impacts[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Efficacy<br \/>\nApplicability<br \/>\nEnvironmental sustainability<br \/>\nReversibility<br \/>\nImpact<br \/>\nQuality of redevelopment<br \/>\nDurability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">****<br \/>\n***<br \/>\n***<br \/>\n**<br \/>\n**<br \/>\n**<br \/>\n****<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Cost and construction logistics[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Monetary cost<br \/>\nConstruction complexity<br \/>\nAvailability (time)<br \/>\nExecution time<br \/>\nMaintenance costs<br \/>\nRegionality<br \/>\nIntegrative interventions<br \/>\nUse restriction[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">**<br \/>\n**<br \/>\n***<br \/>\n**<br \/>\n****<br \/>\n***<br \/>\n***<br \/>\n***<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]Production process[\/vc_column_text][vc_empty_space height=&#8221;8px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/5&#8243;][vc_column_text]Degree of innovation<br \/>\nSustainability[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/5&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">***<br \/>\n***<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Relationship with the indicators of the Risk Analysis Model<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]<em>Formal vulnerability<\/em>: Building albedo &#8211; Roofs; Mitigations elements in the building &#8211; Roofs.<br \/>\n<em>Structural and building services vulnerabilities<\/em>: Building envelope and its efficiency; Roof constructions materials and their thermal resilience.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>References<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]UNI EN ISO 13788:2003. Hygrometric performance of building components and elements. Italian National Standardisation Body. Milan.<br \/>\nUNI EN ISO 10211:2008. Thermal bridges in building construction. Italian National Standardisation Body. Milan.<br \/>\nMinisterial Decree of 26 January 2010 (Italy). Amendment to the Decree of 11 March 2008 on the energy retrofitting of buildings[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text] &lt;- back to home [\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;16133&#8243; img_size=&#8221;600&#215;450&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] MTTM&#8230;.<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16077","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16077","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/comments?post=16077"}],"version-history":[{"count":4,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16077\/revisions"}],"predecessor-version":[{"id":16302,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/16077\/revisions\/16302"}],"wp:attachment":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/media?parent=16077"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}