{"id":15831,"date":"2026-05-13T14:58:10","date_gmt":"2026-05-13T12:58:10","guid":{"rendered":"https:\/\/www.corila.it\/?page_id=15831"},"modified":"2026-06-05T14:51:19","modified_gmt":"2026-06-05T12:51:19","slug":"mttm-uhi-efficientamento-energetico-mic2015","status":"publish","type":"page","link":"https:\/\/www.corila.it\/en\/mttm-uhi-efficientamento-energetico-mic2015\/","title":{"rendered":"MTTM. UHI Efficientamento energetico MIC2015"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: right;\"><a href=\"https:\/\/www.corila.it\/en\/metodologie-tecnologie-tecniche-e-materiali-per-ladeguamento-e-lefficientamento-di-edifici-e-siti-storici\/\">&lt;- back to home<\/a><\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;15842&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221;][\/vc_column][vc_column width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;15840&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221;][\/vc_column][vc_column width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;15838&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221;][\/vc_column][vc_column width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;15844&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4>Methodologies, Technologies, Techniques, and Materials for the Mitigation of Urban Heat Islands and Energy Efficiency of Historic Buildings. MIC 2015 Guidelines<\/h4>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]The <a href=\"https:\/\/www.soprintendenzapdve.beniculturali.it\/la-soprintendenza-informa\/atti-di-indirizzo\/linee-guida-di-indirizzo-per-il-miglioramento-dellefficienza-energetica-nel-patrimonio-culturale\/\" target=\"_blank\" rel=\"noopener\"><strong>Guidelines for Improving Energy Efficiency in Cultural Heritage<\/strong><\/a>, published in 2015 by the <strong>Italian Ministry of Culture<\/strong> (then MiBACT), represent one of the main Italian references for the compatibility between historical heritage conservation and energy consumption reduction.<br \/>\nThe document proposes an integrated approach that considers not only the energy performance of historic buildings, but also their historical, architectural, material, and landscape values. The guidelines promote compatible, reversible, and sustainable interventions, based on prior knowledge of the property and an assessment of the potential impacts of transformations.<br \/>\nParticular attention is paid to the choice of methodologies, technologies, techniques, and materials (MTTM) capable of improving environmental comfort and energy efficiency while limiting permanent alterations to cultural heritage.<\/p>\n<p>In this repository, these guidelines constitute a methodological reference for the identification, classification, and description of MTTMs applicable to historic buildings in the context of phenomena related to Urban Heat Islands (UHI), climate adaptation, and the improvement of indoor environmental quality.<\/p>\n<p>The MTTMs have been reorganized into thematic classes, derived from the main types of intervention described in the 2015 MIC Guidelines:<\/p>\n<ol>\n<li><a href=\"https:\/\/www.corila.it\/en\/mttm_mic2015_1_isolamenti_interni_esterni\/\"><em> Internal and external insulation<\/em><\/a><\/li>\n<li><a href=\"https:\/\/www.corila.it\/en\/mttm_mic2015_2_sostituzione_serramenti\/\"><em> Replacement of windows and doors and installation of glazing<\/em><\/a><\/li>\n<li><a href=\"https:\/\/www.corila.it\/en\/mttm_mic2015_3_interventi_solaio\/\"><em> Interventions on the slab \u2013 Lower horizontal closures<\/em><\/a><\/li>\n<li><a href=\"https:\/\/www.corila.it\/en\/mttm_mic2015_4_applicazione_pellicole_schermi\/\"><em> Application of films and screens \u2013 Insulation and airtightness, solar shading<\/em><\/a><\/li>\n<li><a href=\"https:\/\/www.corila.it\/en\/mttm_mic2015_5_installazione_sistemi_di_luce\/\"><em> Installation of lighting and ventilation systems<\/em><\/a><\/li>\n<li><a href=\"https:\/\/www.corila.it\/en\/mttm_mic2015_6_interventi_umidita_risalita_capillare\/\"><em> Interventions for humidity and capillary rising damp<\/em><\/a><\/li>\n<\/ol>\n<p>The repository offers a synthetic and operational reworking of the original content, aimed at supporting analysis, design, and selection of compatible interventions for historic buildings and sites.[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>The environmental quality of historic buildings<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The indoor environmental quality (IEQ) of historic buildings depends on the interaction between thermal comfort, air quality, visual comfort, and acoustic comfort, aspects that influence user well-being, indoor health, and energy consumption.<br \/>\nThe IEQ assessment generally refers to the UNI EN 15251 and UNI EN ISO 7730 standards, which define parameters relating to temperature, humidity, ventilation, lighting, and sound pressure levels. In historic buildings, these aspects must be integrated with the conservation needs of cultural heritage, considering the effects of environmental parameters on the durability of materials, decorated surfaces, and preserved works of art.<\/p>\n<p>Improving environmental quality can occur through interventions on the building envelope\u2014such as thermal insulation, improved windows and doors, and solar shading systems\u2014or through interventions on air conditioning and ventilation systems. However, the design must maintain a balance between comfort, energy efficiency, compatibility with the historic building, and control of thermohygrometric degradation.<br \/>\nParticular attention must be paid to museums and ecclesiastical buildings, where the control of temperature, relative humidity, lighting, and air quality is essential both for the preservation of cultural heritage and for the enjoyment of the spaces by users. In these contexts, routine maintenance, environmental monitoring, and the adoption of systems compatible with the building&#8217;s historical and architectural characteristics are of great importance<\/p>\n<p><a href=\"https:\/\/www.corila.it\/en\/mttm_mic2015_qualita_ambientale\/\"><em>-&gt; learn more<\/em><\/a>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Interventions on buildings and restoration criteria<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The restoration of historic buildings is based on a historical-critical and scientific approach aimed at the protection, conservation, and transmission of cultural heritage over time.<br \/>\nThe contemporary approach to restoration, however, does not exclude functional, energy, or system improvements, provided they are compatible with the historical, architectural, and material values \u200b\u200bof the building and consistent with the principle of &#8220;integrated conservation&#8221; (Amsterdam Declaration, 1975). In this context, the project takes on the role of synthesis between the needs of protection, safety, comfort, accessibility, and energy efficiency.<\/p>\n<p>Particular attention must be paid to the inclusion of technological systems, which are often highly invasive with respect to pre-existing historical features. Intervention strategies must therefore favor compatible, reversible solutions that are integrated with the building&#8217;s structural behavior, avoiding permanent alterations to the structures and architectural features.<\/p>\n<p>The main theoretical and normative references for restoration\u2014from the Athens Charter (1931) to the Venice Charter (1964), up to the Restoration Charter of 1972\u2014define some fundamental criteria: compatibility, reversibility, minimal intervention, distinguishability between new and old, and respect for the authenticity of the historic asset.<br \/>\nEach intervention therefore requires in-depth preliminary knowledge of the building, based on surveys, diagnostic investigations, and historical-critical analyses, aimed at identifying the most appropriate solutions and any bioclimatic strategies already present in the historic architecture. Restoration is thus an interdisciplinary activity, founded on dialogue between specialists, ongoing research, and design quality.<\/p>\n<p><a href=\"https:\/\/www.corila.it\/en\/mttm_mic2015_interventi_criteri\"><em>-&gt; learn more<\/em><\/a>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>Evaluating the energy performance of a historic building<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The energy performance of a historic building corresponds to the annual amount of energy required to meet the needs of winter and summer air conditioning, domestic hot water production, ventilation, and lighting.<br \/>\nThe energy assessment must consider numerous factors, including the site&#8217;s climatic conditions, the characteristics of the building envelope, the presence of energy production systems, the performance of the systems, and the internal microclimate of the rooms. Overall performance is expressed through the global energy performance index (EPgl), defined according to current European and national regulations and calculated using the UNI Technical Specifications 11300 series.<\/p>\n<p>In historic buildings, energy assessment presents particular challenges due to the difficulty of obtaining reliable data on the thermo-physical characteristics of the structures and the need to maintain compatibility with the historical and architectural values \u200b\u200bof the property. For this reason, it is useful to distinguish the energy contributions related to the envelope, systems, heating, and cooling, in order to obtain a clearer and more targeted diagnosis.<\/p>\n<p>The assessment must be conducted both in the current state and after energy improvement interventions (before and after construction), to verify the actual reduction in energy consumption and the compatibility of the adopted solutions. The results are generally summarized in specific assessment sheets or matrices to support design and authorization activities.Negli edifici storici la valutazione energetica presenta particolari complessit\u00e0 legate alla difficolt\u00e0 di reperire dati affidabili sulle caratteristiche termo-fisiche delle strutture e alla necessit\u00e0 di mantenere compatibilit\u00e0 con i valori storico-architettonici del bene. Per questo motivo risulta utile distinguere i contributi energetici relativi a involucro, impianti, riscaldamento e raffrescamento, cos\u00ec da ottenere una diagnosi pi\u00f9 chiara e mirata.<\/p>\n<p><a href=\"https:\/\/www.corila.it\/en\/mttm_mic2015_prestazione_energetica\/\"><em>-&gt; learn more<\/em><\/a>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>The types of interventions (MTTM)<\/h6>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_column_text]The main types of interventions for improving the energy efficiency of historic buildings include integrated strategies aimed at the <em>building envelope, windows, shading systems, natural ventilation, and humidity control<\/em>. These interventions must reconcile energy consumption reduction, improved environmental comfort, and preservation of the building&#8217;s historical and architectural value, while maintaining material compatibility, reversibility, and proper thermohygrometric balance of historic structures.<\/p>\n<p><em>Internal and external insulation<\/em> interventions primarily concern opaque roofs and walls, using compatible insulation systems, ventilated roofs, thermally insulating plasters, and passive cooling techniques based on natural ventilation, radiation control, and exploitation of the thermal inertia of the masonry. <em>Windows and glass surfaces<\/em>, however, are particularly sensitive elements, as they affect heat loss, natural lighting, ventilation, and acoustic comfort. Strategies include glazing replacement, double glazing, improved airtightness, shading, and controlled ventilation systems.<\/p>\n<p>Another area of focus concerns interventions on <em>slabs and lower enclosures<\/em>, aimed at reducing heat loss and promoting passive cooling by exploiting ground temperatures and geothermal systems compatible with historic buildings. At the same time, <em>solar shading, insulating films, and light control systems<\/em> reduce summer overheating, improve visual comfort, and limit energy consumption while maintaining compatibility with the historic features of the fa\u00e7ades.<\/p>\n<p><em>Natural lighting and ventilation strategies<\/em> include passive systems such as light shelves, solar greenhouses, reflective ducts, and ventilation stacks, which improve indoor environmental quality and reduce the need for mechanical systems. Finally, controlling humidity and rising damp, which are among the main causes of deterioration in historic buildings, is particularly important. Intervention techniques include drainage, waterproofing, physical or chemical barriers, and moisture evacuation systems, including macroporous plaster and electro-osmosis.<\/p>\n<p><a href=\"https:\/\/www.corila.it\/en\/mttm_mic2015_tipologie_interventi\/\"><em>-&gt; learn more<\/em><\/a>[\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][vc_separator color=&#8221;mulled_wine&#8221;][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1776264909590{margin-top: 100px !important;}&#8221;][vc_column][vc_empty_space height=&#8221;64px&#8221;][vc_column_text] &lt;- back to home [\/vc_column_text][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;15842&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221;][\/vc_column][vc_column&#8230;<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-15831","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/15831","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/comments?post=15831"}],"version-history":[{"count":13,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/15831\/revisions"}],"predecessor-version":[{"id":16062,"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/pages\/15831\/revisions\/16062"}],"wp:attachment":[{"href":"https:\/\/www.corila.it\/en\/wp-json\/wp\/v2\/media?parent=15831"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}